Suppr超能文献

骨盆手术中突出的金属器械导致性交困难。

Prominent metalware from pelvic surgery causing dyspareunia.

作者信息

Nambiar Mithun, Heaton Samuel Raymond, Stevenson Andrew John, Bucknill Andrew Thomas

机构信息

Department of Orthopaedic Surgery, The Royal Melbourne Hospital, Parkville, Victoria, Australia.

Department of Surgery (RMH), The University of Melbourne, Royal Melbourne Hospital, Melbourne, Victoria, Australia.

出版信息

BMJ Case Rep. 2017 Jan 6;2017:bcr2016217285. doi: 10.1136/bcr-2016-217285.

Abstract

We present a case of female dyspareunia secondary to metalware placement during extensive pelvic surgery following a motor vehicle accident. The patient initially had an uneventful recovery from her operations. However, she noticed pain with vaginal intercourse, due to a screw tip which was palpable on vaginal examination. X-ray imaging confirmed long screws in the medial part of an anterior column plate, which were impacting on the anterior vaginal wall. Subsequent percutaneous removal of two screws resulted in resolution of her symptoms of painful vaginal intercourse. While the pain from mechanical irritation of the vagina was resolved, the patient continues to have difficulty with intercourse, which is related to hip pain as a result of her initial injury and complex pelvic surgery.

摘要

我们报告一例机动车事故后广泛盆腔手术后因金属器械置入导致女性性交困难的病例。患者术后最初恢复顺利。然而,她在性交时感到疼痛,经阴道检查可触及一个螺钉尖端。X线成像证实前柱钢板内侧有长螺钉,这些螺钉压迫阴道前壁。随后经皮取出两枚螺钉后,她性交疼痛的症状得以缓解。虽然阴道机械性刺激引起的疼痛得到了解决,但患者仍存在性交困难,这与她最初受伤及复杂盆腔手术导致的髋部疼痛有关。