Suppr超能文献

双平面内侧开放楔形高位胫骨截骨术中继发改变与选择性截骨参数的三维关系

Three-dimensional relationships between secondary changes and selective osteotomy parameters for biplane medial open-wedge high tibial osteotomy.

作者信息

Lee Byung Hoon, Ha Chul Won, Moon Sang Won, Chang Minho, Kim Hun Yeong, Park Sin Hyung, Wang Joon Ho

机构信息

Department of Orthopaedic Surgery, Kang-Dong Sacred Heart Hospital, Hallym University Medical Center, Seoul, South Korea.

Department of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea.

出版信息

Knee. 2017 Mar;24(2):362-371. doi: 10.1016/j.knee.2016.11.010. Epub 2017 Feb 4.

Abstract

BACKGROUND

To assess the axial rotational change of distal tibia and posterior tibial slope (PTS) change after OWHTO in 3-D planes and to identify the causal relationship on the effect of variation in the posterior slope angle and rotational errors.

METHODS

A total of 21 patients (23 knees) underwent OWHTO and were evaluated with 3D-CT before and after surgery. Medial proximal tibial angle in the coronal plane, PTS in the sagittal plane, and rotational axis in axial plane were evaluated and compared between pre- and post-operative 3D models constructed by applying reverse-engineering software. As a selective osteotomy parameter, hinge axis and gap ratio were measured in the postoperative 3D models RESULTS: The increasing tendency of internal rotation of the distal tibia after OWHTO was positively related to hinge axis (β=0.730, p=0.001, R=0.546) and gap ratio (β=-0.283, p=0.001, R=0.520), which also showed statistically significant linear correlations to PTS changes after multivariate regression analysis that controlled for the rotational change of the distal tibia (hinge axis: β=0.443, p=0.006; gap ratio: β=0.144, p=0.017).

CONCLUSION

Hinge axis more posterolaterally was related to a greater increase in internal rotation after biplane medial open-wedge HTO, and hinge axis and gap ratio were significant predictors of PTS change after rotational change was controlled for. Hinge axis has to be considered an important independent variable for limiting unintended axial rotation change as well as PTS change as secondary.

CLINICAL RELEVANCE

The relationship of the hinge axis with the rotational change and its influence to PTS change, acknowledged from by-product of the statistical analysis, might provide a deeper understanding of HTO, and should have constitutional effects on the development of HTO procedures and implants.

摘要

背景

评估三维平面上胫骨高位截骨术(OWHTO)后胫骨远端的轴向旋转变化以及胫骨后倾坡度(PTS)变化,并确定后倾角度变化与旋转误差影响之间的因果关系。

方法

共有21例患者(23个膝关节)接受了OWHTO手术,并在术前和术后进行了三维CT评估。通过应用逆向工程软件构建术前和术后的三维模型,评估并比较冠状面的胫骨近端内侧角、矢状面的PTS以及轴位面的旋转轴。作为选择性截骨参数,在术后三维模型中测量铰链轴和间隙比。结果:OWHTO后胫骨远端内旋的增加趋势与铰链轴(β = 0.730,p = 0.001,R = 0.546)和间隙比(β = -0.283, p = 0.001, R = 0.520)呈正相关,在控制胫骨远端旋转变化的多因素回归分析中,它们与PTS变化也显示出统计学上显著的线性相关性(铰链轴:β = 0.443,p = 0.006;间隙比:β = 0.144,p = 0.017)。

结论

双平面内侧开放楔形高位胫骨截骨术后,铰链轴越靠后外侧与内旋增加越大有关,在控制旋转变化后,铰链轴和间隙比是PTS变化的重要预测指标。铰链轴必须被视为限制意外轴向旋转变化以及作为次要因素的PTS变化的重要独立变量。

临床意义

从统计分析的副产品中认识到的铰链轴与旋转变化的关系及其对PTS变化的影响,可能会提供对高位胫骨截骨术更深入的理解,并且应该对高位胫骨截骨术程序和植入物的发展产生结构性影响。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验