Park Hun Soo, Nakagawa Ichiro, Yokoyama Shohei, Wajima Daisuke, Wada Takeshi, Motoyama Yasushi, Kichikawa Kimihiko, Nakase Hiroyuki
Department of Neurosurgery, Nara Medical University, Kashihara, Nara, Japan.
Department of Radiology, Nara Medical University, Kashihara, Nara, Japan.
BMJ Case Rep. 2017 Feb 20;2017:bcr2017013005. doi: 10.1136/bcr-2017-013005.
Metal-induced encephalopathy after stent-assisted coil embolization is extremely rare. The present report describes two patients who presented with symptomatic intracranial parenchymal edematous lesions after stent-assisted coil embolization. A 64-year-old woman underwent stent-assisted coil embolization for a left internal carotid artery aneurysm; 21 days after the procedure she presented with right hand weakness and MRI revealed multifocal white matter lesions. Another woman aged 52 years underwent stent-assisted coil embolization for right vertebral artery aneurysm; 18 days after the procedure she presented with left-sided sensory disturbance and MRI demonstrated multiple white matter lesions. Treatment in both cases resulted in improvement of these lesions after steroid pulse therapy, and the patients had no associated morbidity 4 months after the procedures. Clinicians should monitor for neurologic symptoms and postoperative delayed radiologic parenchymal edematous changes associated with the metal allergic reaction after nitinol stent-assisted coil embolization.
支架辅助弹簧圈栓塞术后金属诱导的脑病极为罕见。本报告描述了两名患者,他们在支架辅助弹簧圈栓塞术后出现了有症状的颅内实质水肿性病变。一名64岁女性因左侧颈内动脉动脉瘤接受了支架辅助弹簧圈栓塞术;术后21天,她出现右手无力,MRI显示多灶性白质病变。另一名52岁女性因右侧椎动脉动脉瘤接受了支架辅助弹簧圈栓塞术;术后18天,她出现左侧感觉障碍,MRI显示多个白质病变。两例患者在接受类固醇脉冲治疗后,这些病变均有所改善,术后4个月患者无相关并发症。临床医生应监测镍钛合金支架辅助弹簧圈栓塞术后与金属过敏反应相关的神经症状和术后延迟的放射学实质水肿变化。