Evaluation of different low-dose multidetector CT and cone beam CT protocols in maxillary sinus imaging: part I-an in vitro study.

作者信息

Almashraqi Abeer A, Ahmed Eman A, Mohamed Nashwa S, Barngkgei Imad H, Elsherbini Nader A, Halboub Esam S

机构信息

1 Department of Oral Radiology, Faculty of Dentistry, Ibb University, Ibb, Yemen.

2 Department of Maxillofacial Surgery and Diagnostic Sciences, College of Dentistry, Jazan University, Jazan, Saudi Arabia.

出版信息

Dentomaxillofac Radiol. 2017 Aug;46(6):20160323. doi: 10.1259/dmfr.20160323. Epub 2017 Apr 12.


DOI:10.1259/dmfr.20160323
PMID:28266870
原文链接:https://pmc.ncbi.nlm.nih.gov/articles/PMC5606275/
Abstract

OBJECTIVES: This in vitro study aimed to assess radiation dose and image quality of different low-dose multidetector CT (MDCT) and CBCT imaging protocols in comparison with the standard MDCT protocol for maxillary sinus imaging. METHODS: Effective dose (E) and image quality of 10 MDCT (changing effective milliampere second starting from 141.3 EmAs to 20 EmAs) and 3 CBCT protocols (changing milliampere second and voxel size) were assessed throughout scanning an anthropomorphic head and neck Alderson Rando phantom. E values were calculated using thermoluminescent dosemeters (TLDs) fixed at 6 sensitive organs (14 sites) on the Rando phantom. Image quality was assessed objectively (by calculating the standard deviation values of the radiographic density of water) and subjectively (by assessing the diagnostic image quality using a four-graded scale: 1 = very good, 2 = good, 3 = acceptable and 4 = unacceptable). RESULTS: Two MDCT protocols (120 kV/32 EmA and 120 kV/25 EmA) had lower radiation doses with statistically significant differences (p < 0.001) compared with that of the standard MDCT protocol (120 kV/141.3 EmA), and they preserved a good diagnostic image quality. One CBCT protocol (120 kV/20 mA) had a reasonable radiation dose and good image quality. There were no statistically significant differences between the above-mentioned lower dose MDCT and CBCT protocols (p > 0.05) with respect to the radiation dose and image quality. CONCLUSIONS: The low-dose MDCT and CBCT protocols are viable methods for maxillary sinus examination as evaluated using the above-mentioned phantom that yield a good diagnostic image quality using E approximately 7 and 11 times lower than that of the standard MDCT, respectively. These findings were evaluated in the in vivo part of this project.

摘要

相似文献

[1]
Evaluation of different low-dose multidetector CT and cone beam CT protocols in maxillary sinus imaging: part I-an in vitro study.

Dentomaxillofac Radiol. 2017-8

[2]
Performance of cone-beam computed tomography and multidetector computed tomography in diagnostic imaging of the midface: A comparative study on Phantom and cadaver head scans.

Eur Radiol. 2016-5-11

[3]
Comparison of the Radiation Dose from Cone Beam Computed Tomography and Multidetector Computed Tomography in Examinations of the Hand.

Rofo. 2016-5

[4]
Surface radiation dose comparison of a dedicated extremity cone beam computed tomography (CBCT) device and a multidetector computed tomography (MDCT) machine in pediatric ankle and wrist phantoms.

PLoS One. 2017-6-1

[5]
Cone beam CT paranasal sinuses versus standard multidetector and low dose multidetector CT studies.

Am J Otolaryngol. 2016

[6]
Metallic artifacts from internal scaphoid fracture fixation screws: comparison between C-arm flat-panel, cone-beam, and multidetector computed tomography.

Invest Radiol. 2014-8

[7]
A dose-neutral image quality comparison of different CBCT and CT systems using paranasal sinus imaging protocols and phantoms.

Eur Arch Otorhinolaryngol. 2022-9

[8]
Using cone-beam CT as a low-dose 3D imaging technique for the extremities: initial experience in 50 subjects.

Skeletal Radiol. 2015-6

[9]
Dose and image quality of cone-beam computed tomography as compared with conventional multislice computed tomography in abdominal imaging.

Invest Radiol. 2014-10

[10]
Experiences with image quality and radiation dose of cone beam computed tomography (CBCT) and multidetector computed tomography (MDCT) in pediatric extremity trauma.

Skeletal Radiol. 2020-12

引用本文的文献

[1]
[Applications of cone beam computed tomography of the craneofacial structure in medical specialties. A review].

Rev Cient Odontol (Lima). 2022-3-30

[2]
Comparison of Diagnostic Quality of Multidetector Computed Tomography and Cone-Beam Computed Tomography in High and Low Resolution Modes for Assessment of the Nasal Cavity.

World J Plast Surg. 2023

[3]
Transfer learning in diagnosis of maxillary sinusitis using panoramic radiography and conventional radiography.

Oral Radiol. 2023-7

[4]
The Combination of Panoramic Imaging and Waters' Projection Contributes to the Diagnosis of Odontogenic Maxillary Sinusitis.

Kobe J Med Sci. 2021-4-21

[5]
Cone-beam computed tomographic imaging of silent sinus syndrome: A case series and a literature review.

Imaging Sci Dent. 2020-12

[6]
Odontogenic causes complicating the chronic rhinosinusitis diagnosis.

Clin Oral Investig. 2021-3

[7]
Radiation dose in non-dental cone beam CT applications: a systematic review.

Radiol Med. 2018-6-5

本文引用的文献

[1]
Cone beam CT paranasal sinuses versus standard multidetector and low dose multidetector CT studies.

Am J Otolaryngol. 2016

[2]
Clinical practice guideline (update): adult sinusitis.

Otolaryngol Head Neck Surg. 2015-4

[3]
Comparative study of image quality and radiation dose of cone beam and low-dose multislice computed tomography--an in-vitro investigation.

Clin Oral Investig. 2014-1

[4]
Assessment of the effective doses from two dental cone beam CT devices.

Dentomaxillofac Radiol. 2013-2-18

[5]
Occurrence of maxillary sinus abnormalities detected by cone beam CT in asymptomatic patients.

BMC Oral Health. 2012-8-10

[6]
Associations between maxillary sinus mucosal thickening and apical periodontitis using cone-beam computed tomography scanning: a retrospective study.

J Endod. 2012-6-20

[7]
Comparison of spatial and contrast resolution for cone-beam computed tomography scanners.

Oral Surg Oral Med Oral Pathol Oral Radiol. 2012-5-15

[8]
CT radiation dose optimization and estimation: an update for radiologists.

Korean J Radiol. 2011-12-23

[9]
Effective doses from cone beam CT investigation of the jaws.

Dentomaxillofac Radiol. 2012-1

[10]
Cone-beam computed tomography evaluation of maxillary sinusitis.

J Endod. 2011-4-16