We investigated d,1 [99mTc]hexamethylpropyleneamine oxime complex (HM-PAO) as a tracer for quantitative measurement of local cerebral blood flow (LCBF) in a series of awake male rats. LCBF measurements with HM-PAO were compared to those of two other tracers, [14C] iodoantipyrine (IAP) and [201Tl]diethyldithiocarbamate (DDC), using quantitative double and triple tracer digital autoradiography. LCBF values with HM-PAO averaged 64% those of IAP and were generally linearly related. Detailed analysis suggested that the underestimation of LCBF by HM-PAO was related to blood constituent binding and/or rapid conversion to a noncerebrophilic compound, as well as noninstantaneous cerebral trapping, rather than to diffusion limitation.
我们在一系列清醒雄性大鼠中研究了消旋[99mTc]六甲基丙烯胺肟复合物(HM-PAO)作为定量测量局部脑血流量(LCBF)的示踪剂。使用定量双示踪剂和三示踪剂数字放射自显影技术,将用HM-PAO测量的LCBF与另外两种示踪剂[14C]碘安替比林(IAP)和[201Tl]二乙基二硫代氨基甲酸盐(DDC)的测量结果进行比较。HM-PAO的LCBF值平均为IAP的64%,且通常呈线性相关。详细分析表明,HM-PAO对LCBF的低估与血液成分结合和/或快速转化为非亲脑化合物以及非瞬时脑摄取有关,而非扩散限制。