P1294Evaluation of right atrium mechanics and relation with loading conditions by speckle tracking echocardiography.

作者信息

Unlu S

机构信息

Catholic University of Leuven, University Hospital Gasthuisberg, Dept of Cardiovascular Diseases, Leuven, Belgium.

出版信息

Eur Heart J Cardiovasc Imaging. 2016 Dec 1;17(suppl_2):ii277-ii280. doi: 10.1093/ehjci/jew266.003.

Abstract

PURPOSE

The aim of this study is to evaluate the right atrial (RA) mechanics and change in echocardiographic parameters used for assessment of RA by examining the end stage kidney patients before and after the hemodialysis (HD).

METHODS

Patients between 18 and 85 years of age, receiving HD for at least 6 months were included. The echocardiographic images were obtained before and after hemodialysis therapy. Two-dimensional speckle tracking strain analysis was performed for right atrium in 62 patients. Reference points for analysis are set on the "P" waves. RA reservoir, conduit and contraction phase longitudinal strain (Figure 1) and strain rates (Figure 2) were calculated. The changes in echocardiographic methods before and after hemodialysis were examined. Correlation between volume depletion and change in echocardiographic parameters were calculated.

RESULTS

62 patients (49.7 ± 16.9 years of age, 22 women) were included in study. The mean volume of ultrafiltration was 2958.12 ± 1050.5 ml . The chamber sizes RA are decreased after hemodialysis (RA major diameter; 4.74 ± 0.62 cm vs. 4.46 ± 0.54 cm p<0.001, RA area; 13.8 ± 3.0 cm2 vs. 10.6 ± 2.8 cm2 p<0.001). Two dimensional speckle tracking analysis showed that; RA reservoir phase strain (% 45.60 ± 10.8 vs. % 38.15 ± 8.11 p<0.001). RA conduit phase strain rate (-1.46 ± 0.82 s-1 vs. -1.2 ± 0.56 s-1 p<0.001) measurements are volume dependent. RA reservoir phase strain rate (2.25 ± 0.65 s- vs. 2.5 ± 0.54 s-1 p:0.091) RA contraction strain (% -16.73 ± 6.8 vs. % -16.35 ± 7.1 p:0.835) and RA contraction strain rate (-2.15 ± 0.95 s-1 vs. -2.21 ± 0.72 s-1 p:0.596) are volume independent parameters. RA reservoir phase strain (r=0.332. p:0.008) showed significant correlation with the ultra filtrated volume.

CONCLUSION

Strain rates of RA reservoir phase and RA contraction and RA contraction strain are found to be volume independent measurements obtained by speckle tracking. Explaining RA mechanics with echocardiography is an easy and repeatable assessment which also elucidates more about cardiac pathophysiology and hemodynamics of patients. Moreover defining novel volume independent parameters for evaluation of RA would contribute to clinical perspectives of patients. Abstract P1294 Figure.

UNLABELLED

Abstract P1294 Figure.

摘要

目的

本研究旨在通过检查终末期肾病患者血液透析(HD)前后的情况,评估右心房(RA)力学及用于评估RA的超声心动图参数的变化。

方法

纳入年龄在18至85岁之间、接受HD至少6个月的患者。在血液透析治疗前后获取超声心动图图像。对62例患者的右心房进行二维斑点追踪应变分析。分析的参考点设置在“P”波上。计算RA储存、管道和收缩期纵向应变(图1)及应变率(图2)。检查血液透析前后超声心动图方法的变化。计算容量减少与超声心动图参数变化之间的相关性。

结果

62例患者(年龄49.7±16.9岁,女性22例)纳入研究。平均超滤量为2958.12±1050.5毫升。血液透析后RA腔大小减小(RA大直径;4.74±0.62厘米对4.46±0.54厘米,p<0.001;RA面积;13.8±3.0平方厘米对10.6±2.8平方厘米,p<0.001)。二维斑点追踪分析显示;RA储存期应变(%45.60±10.8对%38.15±8.11,p<0.001)。RA管道期应变率(-1.46±0.82秒-1对-1.2±0.56秒-1,p<0.001)测量值与容量有关。RA储存期应变率(2.25±0.65秒对2.5±0.54秒-1,p:0.091)、RA收缩应变(%-16.73±6.8对%-16.35±7.1,p:0.835)和RA收缩应变率(-2.15±0.95秒-1对-2.21±0.72秒-1,p:0.596)是与容量无关的参数。RA储存期应变(r=0.332,p:0.008)与超滤量显著相关。

结论

发现RA储存期应变率、RA收缩期及RA收缩应变是通过斑点追踪获得的与容量无关的测量值。用超声心动图解释RA力学是一种简单且可重复的评估方法,它还能更清楚地阐明患者的心脏病理生理学和血流动力学。此外,定义用于评估RA的新的与容量无关的参数将有助于患者的临床观察。摘要P1294图。

未标注

摘要P129图。