Suppr超能文献

Septic Shock due to Implantable Cardiac Defibrillator Related Infection.

作者信息

Palmer David, Khand Aleem

机构信息

Aintree Cardiac Centre and Department of Anaesthetics and Critical Care, University Hospital Aintree, Liverpool, UK.

出版信息

J Atr Fibrillation. 2011 Feb 22;3(5):346. doi: 10.4022/jafib.346. eCollection 2011 Feb-Apr.

Abstract

Infection is an important complication of cardiac device implantation. We report the case of a 61 year old patient presenting with septic shock caused by cardiac device infection (CDI) three-weeks after device implantation. At initial presentation, there was an absence of both localising signs and echocardiographic evidence of CDI. Later, Staphylococcus aureus was cultured from blood and the pre-pectoral pocket. 48 hours after admission the device and leads were explanted in theatre by simple traction. Despite appropriate antibiotics and full supportive care (including haemofiltration, ventilation and inotropic support), the patient died on day six. Cardiac device infection may present with septic shock in the absence of localising features. A high index of suspicion is required, particularly for early CDI.

摘要

相似文献

1
Septic Shock due to Implantable Cardiac Defibrillator Related Infection.
J Atr Fibrillation. 2011 Feb 22;3(5):346. doi: 10.4022/jafib.346. eCollection 2011 Feb-Apr.
3
The role of swab and tissue culture in the diagnosis of implantable cardiac device infection.
Pacing Clin Electrophysiol. 2005 Dec;28(12):1276-81. doi: 10.1111/j.1540-8159.2005.00268.x.
4
Management and outcome of permanent pacemaker and implantable cardioverter-defibrillator infections.
J Am Coll Cardiol. 2007 May 8;49(18):1851-9. doi: 10.1016/j.jacc.2007.01.072. Epub 2007 Apr 23.
7
Cardiac device infections: getting to the heart of the matter.
Curr Opin Infect Dis. 2006 Aug;19(4):345-8. doi: 10.1097/01.qco.0000235160.78302.24.
8
Cardiac device-related endocarditis: 31-Years' experience.
J Cardiol. 2013 Feb;61(2):175-80. doi: 10.1016/j.jjcc.2012.08.019. Epub 2012 Nov 17.
9
[Value of pulse indicator continuous cardiac output monitoring of cardiac function in septic shock patients: a prospective study].
Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2015 Jan;27(1):22-7. doi: 10.3760/cma.j.issn.2095-4352.2015.01.006.
10
Device-related infection among patients with pacemakers and implantable defibrillators: incidence, risk factors, and consequences.
J Cardiovasc Electrophysiol. 2010 Jul;21(7):786-90. doi: 10.1111/j.1540-8167.2009.01690.x. Epub 2010 Jan 22.

本文引用的文献

1
Pacemaker infections: a 10-year experience.
Heart Lung Circ. 2007 Dec;16(6):434-9. doi: 10.1016/j.hlc.2007.02.097. Epub 2007 Apr 8.
2
Renal insufficiency and the risk of infection from pacemaker or defibrillator surgery.
Pacing Clin Electrophysiol. 2006 Feb;29(2):142-5. doi: 10.1111/j.1540-8159.2006.00307.x.
3
Septic shock induced from an implantable cardioverter-defibrillator lead-associated Candida albicans vegetation.
J Interv Card Electrophysiol. 2005 Oct;14(1):55-9. doi: 10.1007/s10840-005-3246-x.
6
Pacemaker infective endocarditis.
Am J Cardiol. 1998 Aug 15;82(4):480-4. doi: 10.1016/s0002-9149(98)00365-8.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验