基于磁共振失谐的全髋关节置换术后金属磨屑评估

Off-resonance based assessment of metallic wear debris near total hip arthroplasty.

机构信息

Department of Radiology, Medical College of Wisconsin, Milwaukee, Wisconsin, USA.

Division of Radiology and Imaging, Hospital for Special Surgery, New York, New York, USA.

出版信息

Magn Reson Med. 2018 Mar;79(3):1628-1637. doi: 10.1002/mrm.26807. Epub 2017 Jun 22.

Abstract

PURPOSE

The presence of metallic debris near total hip arthroplasty can have a significant impact on longitudinal patient management. Methods for magnetic resonance imaging-based quantification of metallic debris near painful total hip replacements are described and applied to cohorts of symptomatic and control subject cases.

METHODS

A combination of metal artifact reduction, off-resonance mapping, off-resonance background removal, and spatial clustering methods are utilized to quantify off-resonance signatures in cases of suspected metallosis. These methods are applied to a cohort of symptomatic hip arthroplasties composed of cobalt-chromium alloys. Magnetostatic simulations and theoretical principles are used to illuminate the potential sources of the measured off-resonance effects. Reported metrics from histological tissue assays extracted during surgical revision procedures are also correlated with the proposed magnetic resonance imaging-based quantification results.

RESULTS

The presented methods identified quantifiable metallosis signatures in more than 70% of the symptomatic and none of the control cases. Preliminary correlations of the MR data with direct histological evaluation of retrieved tissue samples indicate that the observed off-resonance effect may be related to tissue necrosis.

CONCLUSIONS

Magnetostatic simulations, theoretical principles, and preliminary histological trends suggest that disassociated cobalt is the source of the observed off-resonance signature. Magn Reson Med 79:1628-1637, 2018. © 2017 International Society for Magnetic Resonance in Medicine.

摘要

目的

全髋关节置换术附近的金属碎屑的存在会对患者的长期管理产生重大影响。描述了基于磁共振成像的定量评估疼痛性全髋关节置换术附近金属碎屑的方法,并将其应用于症状性和对照组病例队列。

方法

采用金属伪影减少、离共振映射、离共振背景去除和空间聚类方法的组合,对疑似金属沉着症病例进行离共振特征的定量。这些方法应用于由钴铬合金组成的症状性髋关节置换术队列。静磁模拟和理论原理用于阐明测量的离共振效应的潜在来源。还将从手术翻修过程中提取的组织学组织分析报告的指标与提出的基于磁共振成像的定量结果进行了相关性分析。

结果

所提出的方法在超过 70%的症状性病例中确定了可量化的金属沉着症特征,但在对照组病例中均未发现。MR 数据与回收组织样本的直接组织学评估的初步相关性表明,观察到的离共振效应可能与组织坏死有关。

结论

静磁模拟、理论原理和初步的组织学趋势表明,游离钴是观察到的离共振特征的来源。磁共振医学 79:1628-1637, 2018。©2017 年国际磁共振学会。

相似文献

3
The imaging appearances of metallosis.金属沉着症的影像学表现。
Skeletal Radiol. 2008 Jan;37(1):59-62. doi: 10.1007/s00256-007-0362-y. Epub 2007 Sep 18.
10
Systemic toxicity related to metal hip prostheses.与金属髋关节假体相关的全身毒性
Clin Toxicol (Phila). 2014 Sep-Oct;52(8):837-47. doi: 10.3109/15563650.2014.944977. Epub 2014 Aug 16.

引用本文的文献

4
Clinical magnetic resonance imaging of arthroplasty at 1.5 T.关节置换术的 1.5T 临床磁共振成像
J Orthop Res. 2020 Jul;38(7):1455-1464. doi: 10.1002/jor.24606. Epub 2020 Feb 4.

本文引用的文献

4
Intracranial Gadolinium Deposition after Contrast-enhanced MR Imaging.颅内钆沉积与对比增强磁共振成像后。
Radiology. 2015 Jun;275(3):772-82. doi: 10.1148/radiol.15150025. Epub 2015 Mar 5.
7
MR imaging of hip arthroplasty implants.髋关节置换植入物的磁共振成像
Radiographics. 2014 Jul-Aug;34(4):E106-32. doi: 10.1148/rg.344140010.
9
Cobalt triggers necrotic cell death and atrophy in skeletal C2C12 myotubes.钴会引发骨骼肌 C2C12 肌管的坏死性细胞死亡和萎缩。
Toxicol Appl Pharmacol. 2013 Sep 1;271(2):196-205. doi: 10.1016/j.taap.2013.05.005. Epub 2013 May 14.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验