Department of Radiology, Xijing Hospital, Fourth Military Medical University, 17 Changle Road, Xi'an, Shaanxi, 710032, China.
Department of MRI, Shaanxi Provincial People's Hospital, Xi'an, Shaanxi, 710032, China.
Eur Radiol. 2017 Dec;27(12):5204-5214. doi: 10.1007/s00330-017-4843-7. Epub 2017 Jun 27.
This meta-analysis was undertaken to review the diagnostic accuracy of PI-RADS V2 for prostate cancer (PCa) detection with multiparametric MR (mp-MR).
A comprehensive literature search of electronic databases was performed by two observers independently. Inclusion criteria were original research using the PI-RADS V2 system in reporting prostate MRI. The methodological quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. Data necessary to complete 2 × 2 contingency tables were obtained from the included studies.
Thirteen studies (2,049 patients) were analysed. This is an initial meta-analysis of PI-RADs V2 and the overall diagnostic accuracy in diagnosing PCa was as follows: pooled sensitivity, 0.85 (0.78-0.91); pooled specificity, 0.71 (0.60-0.80); pooled positive likelihood ratio (LR+), 2.92 (2.09-4.09); pooled negative likelihood ratio (LR-), 0.21 (0.14-0.31); pooled diagnostic odds ratio (DOR), 14.08 (7.93-25.01), respectively. Positive predictive values ranged from 0.54 to 0.97 and negative predictive values ranged from 0.26 to 0.92.
Currently available evidence indicates that PI-RADS V2 appears to have good diagnostic accuracy in patients with PCa lesions with high sensitivity and moderate specificity. However, no recommendation regarding the best threshold can be provided because of heterogeneity.
• PI-RADS V2 shows good diagnostic accuracy for PCa detection. • Initially pooled specificity of PI-RADS v2 remains moderate. • PCa detection is increased by experienced radiologists. • There is currently a high heterogeneity in prostate diagnostics with MRI.
本荟萃分析旨在评估 PI-RADS V2 系统在多参数磁共振(mp-MR)前列腺癌(PCa)检测中的诊断准确性。
两名观察者独立对电子数据库进行全面文献检索。纳入标准为使用 PI-RADS V2 系统报告前列腺 MRI 的原始研究。使用诊断准确性研究质量评估工具(QUADAS-2)评估方法学质量。从纳入的研究中获取完成 2×2 列联表所需的数据。
共分析了 13 项研究(2049 例患者)。这是对 PI-RADs V2 的初步荟萃分析,诊断 PCa 的总体诊断准确性如下:合并敏感度为 0.85(0.78-0.91);合并特异度为 0.71(0.60-0.80);合并阳性似然比(LR+)为 2.92(2.09-4.09);合并阴性似然比(LR-)为 0.21(0.14-0.31);合并诊断比值比(DOR)为 14.08(7.93-25.01)。阳性预测值范围为 0.54 至 0.97,阴性预测值范围为 0.26 至 0.92。
目前的证据表明,PI-RADS V2 似乎对 PCa 病变具有较高的诊断准确性,敏感度高,特异度适中。然而,由于存在异质性,无法提供最佳阈值的推荐。
• PI-RADS V2 对 PCa 检测具有良好的诊断准确性。
• 最初的 PI-RADS v2 汇总特异性仍然适中。
• 经验丰富的放射科医生可提高 PCa 的检出率。
• 目前 MRI 前列腺诊断存在较高的异质性。