Fernández-Vigo J I, de-Pablo Gómez de Liaño L, Sánchez-Guillen I, Macarro-Merino A, Fernández-Vigo C, García-Feijóo J, Fernández-Vigo J A
Departamento de Oftalmología, Hospital Universitario Clínico San Carlos, Instituto de Investigación Sanitaria San Carlos (IdISSC), Madrid, España; Centro Internacional de Oftalmología Avanzada, Madrid, España.
Centro Internacional de Oftalmología Avanzada, Madrid, España; Departamento de Oftalmología, Hospital Universitario 12 de Octubre, Madrid, España.
Arch Soc Esp Oftalmol (Engl Ed). 2018 Feb;93(2):53-59. doi: 10.1016/j.oftal.2017.06.008. Epub 2017 Jul 22.
To evaluate different anterior segment parameters in eyes with pseudoexfoliation (PSX), fellow eyes, and controls using optical coherence tomography and a Scheimpflug imaging system.
Three groups were studied: 44 eyes of 44 patients with PSX, 30 clinically unaffected fellow eyes, and 148 eyes of 148 healthy controls. The anterior chamber depth and volume, corneal volume and thickness, pupil diameter and corneal densitometry were measured using a Scheimpflug imaging system (Pentacam, Oculus Inc.; Wetzlar, Germany). The angle width, the length and area of the trabecular meshwork, and the iris thickness were measured using an optical coherence tomography RTVue 100 device (Optovue, Fremont, CA, USA). The presence of PSX deposits was also assessed by OCT.
There were no differences in the anterior chamber volume or depth in the corneal volume or central thickness (P≥.228). The corneal densitometry was similar between PSX and fellow eyes; however it was greater than in the control group (P<.001). As regards the parameters measured by OCT, there were no differences in the angle width or in the trabecular meshwork size between the 3 groups; however, the iris was thinner in controls (P=.005). In all patients the PSX deposits were correctly visualised by OCT after the identification by biomicroscopy.
There were no differences in the anterior segment biometric measurements between patients with PSX and controls, although the corneal densitometry and iris thickness were greater in the PSX and fellow eyes groups.
使用光学相干断层扫描和眼前节分析系统评估假性剥脱综合征(PSX)患眼、对侧眼及对照组的不同眼前节参数。
研究分为三组:44例PSX患者的44只患眼、30例临床未受累的对侧眼以及148例健康对照者的148只眼。使用眼前节分析系统(Pentacam,德国奥culus公司;德国韦茨拉尔)测量前房深度和容积、角膜容积和厚度、瞳孔直径及角膜密度。使用光学相干断层扫描RTVue 100设备(美国加利福尼亚州弗里蒙特市Optovue公司)测量房角宽度、小梁网长度和面积以及虹膜厚度。还通过光学相干断层扫描评估PSX沉积物的存在情况。
前房容积或深度、角膜容积或中央厚度方面无差异(P≥0.228)。PSX患眼与对侧眼的角膜密度相似,但高于对照组(P<0.001)。关于光学相干断层扫描测量的参数,三组之间房角宽度或小梁网大小无差异;然而,对照组的虹膜较薄(P = 0.005)。在所有患者中,经生物显微镜识别后,光学相干断层扫描均能正确显示PSX沉积物。
PSX患者与对照组的眼前节生物测量参数无差异,尽管PSX患眼组和对侧眼组的角膜密度和虹膜厚度更大。