Suppr超能文献

技术说明:评估数字折射计以估计泽西牛犊血清免疫球蛋白 G 浓度和被动传递。

Technical note: Evaluation of digital refractometers to estimate serum immunoglobulin G concentration and passive transfer in Jersey calves.

机构信息

Department of Animal Science, Iowa State University, Ames 50014.

North Country Regional Agriculture Team, Cornell University, Ithaca, NY 14853.

出版信息

J Dairy Sci. 2017 Oct;100(10):8438-8442. doi: 10.3168/jds.2017-12847. Epub 2017 Jul 26.

Abstract

Previous data have demonstrated that refractometers can be used to estimate serum IgG, and that a cut-point of 7.8% Brix should be used to identify failure of passive transfer (FPT) in 1-d-old Holstein calves. The objective of the present study was to validate the use of refractometry to estimate serum IgG concentrations and evaluate FPT in Jersey calves. Blood samples (n = 97) were obtained from 1- to 3-d-old Jersey calves and centrifuged at 3,300 × g for 20 min at 25°C. Serum was analyzed for % Brix, total protein (TP), and refractive index (nD) using a Sper Scientific Digital Refractometer (model #300036, Sper Scientific, Scottsdale, AZ) within 12 h of sampling. Samples were then frozen and later analyzed in the laboratory for IgG by radial immunodiffusion. The mean serum IgG concentration for all calves was 23.7 mg/mL (SD = 12.5), with a range of 2.3 to 65.5 mg/mL. Mean serum % Brix was 8.9 (SD = 1.1; range 6.5 to 12.0). Serum % Brix was moderately correlated with IgG concentration (r = 0.77). Total protein and IgG were moderately correlated (r = 0.790). Regression was used to determine cut-points for approximately 10, 12, and 14 mg of IgG/mL and to determine the sensitivity and specificity of refractometry to identify FPT (serum IgG <10 mg/mL at 24 h of life). Brix cut-points analyzed were 7.1, 7.3, and 7.6%; TP cut-points were 4.6, 5.0, and 5.5 g/dL; and nD cut-points were 1.34332, 1.34271, and 1.3448, respectively, for 10, 12, and 14 mg of IgG/mL. The 7.3% Brix and 4.6 g/dL TP cut-points resulted in the greatest percentage of samples being correctly classified. These data suggest that digital refractometry is an acceptable and rapid method to estimate immunoglobulin G in Jersey calf serum.

摘要

先前的数据表明,折射仪可用于估计血清 IgG,并且在 1 日龄荷斯坦小牛中,应使用 7.8% Brix 的切点来识别被动传递失败(FPT)。本研究的目的是验证折射仪用于估计血清 IgG 浓度和评估泽西小牛 FPT 的使用。从 1 至 3 日龄的泽西小牛中采集血液样本(n = 97),在 25°C 下以 3300×g 离心 20 min。在采样后 12 小时内,使用 Sper Scientific Digital 折射计(型号#300036,Sper Scientific,斯科茨代尔,AZ)分析血清的%Brix、总蛋白(TP)和折射率(nD)。然后将样品冷冻,并在实验室中通过放射免疫扩散分析 IgG。所有小牛的平均血清 IgG 浓度为 23.7 mg/mL(SD = 12.5),范围为 2.3 至 65.5 mg/mL。平均血清%Brix 为 8.9(SD = 1.1;范围 6.5 至 12.0)。血清%Brix 与 IgG 浓度中度相关(r = 0.77)。总蛋白和 IgG 中度相关(r = 0.790)。回归用于确定约 10、12 和 14 mg/mL IgG 的切点,并确定折射仪识别 FPT(出生后 24 小时血清 IgG <10 mg/mL)的敏感性和特异性。分析的 Brix 切点分别为 7.1、7.3 和 7.6%;TP 切点分别为 4.6、5.0 和 5.5 g/dL;nD 切点分别为 1.34332、1.34271 和 1.3448,分别对应于 10、12 和 14 mg/mL IgG。7.3%Brix 和 4.6 g/dL TP 切点导致最大比例的样本被正确分类。这些数据表明,数字折射仪是一种可接受且快速的方法,可用于估计泽西小牛血清中的免疫球蛋白 G。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验