Department of Cardiac Anesthesiology, University Hospital Ulm, Ulm, Germany.
Blood Purif. 2017;44(3):210-216. doi: 10.1159/000477454. Epub 2017 Aug 9.
BACKGROUND/AIMS: During continuous renal replacement therapy, relevant losses of nutritional substrates, vitamins, and trace elements via the filter may occur. We investigated filter lifetime efficiency during a 72-h treatment period.
This prospective study included 40 patients undergoing citrate continuous veno-venous hemodialysis (CVVHD). The elimination rates were measured at 24, 48, and 72 h. To assess the influence of filter lifetime, we determined substrate loss every 24 h over a 72-h interval.
Filter lifetime did not affect the loss of ionized calcium, inorganic phosphate, magnesium, zinc, folic acid, and vitamin B12. Nevertheless, we did observe clinically significant loss of ionized calcium and inorganic phosphate during CVVHD that required supplementation.
CVVHD leads to significant loss of ionized calcium and inorganic phosphate that is independent of the filter lifetime.
背景/目的:在连续肾脏替代治疗过程中,通过过滤器可能会丢失相关的营养底物、维生素和微量元素。我们研究了在 72 小时治疗期间过滤器的使用寿命效率。
这项前瞻性研究纳入了 40 例行柠檬酸盐连续静脉-静脉血液透析(CVVHD)的患者。在 24、48 和 72 小时时测量清除率。为了评估过滤器使用寿命的影响,我们在 72 小时的间隔内每 24 小时测定一次底物的损失。
过滤器的使用寿命并不影响离子钙、无机磷、镁、锌、叶酸和维生素 B12 的丢失。然而,我们确实观察到 CVVHD 过程中离子钙和无机磷的临床显著丢失,需要补充。
CVVHD 导致显著的离子钙和无机磷丢失,与过滤器的使用寿命无关。