Abstract

BACKGROUND

Fast and reliable diagnostics are important in febrile patients admitted to the emergency department. Current urine diagnostics are fast but moderately reliable or reliable but time consuming. Flow cytometry (FC) is a new promising technique in the diagnostics of complicated urinary tract infections by counting bacteria in urine samples. The aim of this study is to improve the FC method by counting only viable bacteria.

METHODS

Urine was obtained from 135 consecutive febrile patients at the emergency department. According to protocol regular diagnostic urine tests were performed. In addition, FC counting of viable and non-viable bacteria was executed after staining with thiazole orange and propidium iodide. All test results were compared to the results of urine culture (≥ 10 colony forming units/mL).

RESULTS

At a cut-off value of 2.01 × 10 viable bacteria/mL the sensitivity was 100% and specificity was 78.4% (AUC-value 0.955 on ROC-curve). Spearman correlation test exhibited a higher correlation for flow cytometric counting of only viable bacteria than counting of all bacteria (0.59 vs. 0.37). Using ROC-curves, the AUC-values for FC counting of all bacteria, only viable bacteria and Gram staining were respectively 0.935, 0.955, and 0.968 (P > 0.05).

CONCLUSION

FC counting of only viable bacteria can predict quickly and reliably positive and negative urine cultures in febrile patients admitted to the emergency department. It can help to improve the speed and accuracy of the diagnostic procedure at the emergency department. © 2017 Clinical Cytometry Society.

摘要

背景

在急诊收治的发热患者中,快速可靠的诊断至关重要。目前的尿液诊断方法速度较快,但可靠性中等;或者可靠但耗时较长。流式细胞术(FC)是一种新的有前途的技术,可通过计算尿液样本中的细菌来诊断复杂的尿路感染。本研究的目的是通过仅计数有活力的细菌来改进 FC 方法。

方法

从急诊部的 135 例连续发热患者中获得尿液。根据方案进行了常规诊断性尿液检查。此外,用噻唑橙和碘化丙啶染色后,执行 FC 计数有活力和无活力的细菌。将所有测试结果与尿液培养(≥10 个菌落形成单位/ml)的结果进行比较。

结果

在 2.01×10 个有活力细菌/ml 的截断值下,灵敏度为 100%,特异性为 78.4%(ROC 曲线的 AUC 值为 0.955)。Spearman 相关检验显示,仅计数有活力细菌的流式细胞术计数与计数所有细菌的相关性更高(0.59 比 0.37)。使用 ROC 曲线,FC 计数所有细菌、仅计数有活力细菌和革兰氏染色的 AUC 值分别为 0.935、0.955 和 0.968(P>0.05)。

结论

FC 计数仅存活细菌可以快速可靠地预测急诊收治发热患者的尿液培养阳性和阴性结果。它有助于提高急诊处诊断程序的速度和准确性。© 2017 临床细胞技术学会。