Western Seoul Center, Korea Basic Science Institute, 150 Bugahyeon-ro, Seodaemun-gu, Seoul 03759, Republic of Korea; Department of Chemistry and Nano Science, Ewha Womans University, 52 Ewhayeodae-gil, Seodaemun-gu, Seoul 03760, Republic of Korea.
Western Seoul Center, Korea Basic Science Institute, 150 Bugahyeon-ro, Seodaemun-gu, Seoul 03759, Republic of Korea; Department of Food Science & Engineering, Ewha Womans University, 52 Ewhayeodae-gil, Seodaemun-gu, Seoul 03760, Republic of Korea.
Anal Chim Acta. 2017 Sep 1;984:223-231. doi: 10.1016/j.aca.2017.06.052. Epub 2017 Jul 6.
A sensitive and selective capillary electrophoresis-mass spectrometry (CE-MS) method for determination of saturated fatty acids (FAs) was developed by using dicationic ion-pairing reagents forming singly charged complexes with anionic FAs. For negative ESI detection, 21 anionic FAs at pH 10 were separated using ammonium formate buffer containing 40% acetonitrile modifier in normal polarity mode in CE by optimizing various parameters. This method showed good separation efficiency, but the sensitivity of the method to short-chain fatty acids was quite low, causing acetic and propionic acids to be undetectable even at 100 mgL in negative ESI-MS detection. Out of the four dicationic ion-pairing reagents tested, N,N'-dibutyl 1,1'-pentylenedipyrrolidium infused through a sheath-liquid ion source during CE separation was the best reagent regarding improved sensitivity and favorably complexed with anionic FAs for detection in positive ion ESI-MS. The monovalent complex showed improved ionization efficiency, providing the limits of detection (LODs) for 15 FAs ranging from 0.13 to 2.88 μg/mL and good linearity (R > 0.99) up to 150 μg/mL. Compared to the negative detection results, the effect was remarkable for the detection of short- and medium-chain fatty acids. The optimized CE-paired ion electrospray (PIESI)-MS method was utilized for the determination of FAs in cheese and coffee with simple pretreatment. This method may be extended for sensitive analysis of unsaturated fatty acids.
一种灵敏且选择性的毛细管电泳-质谱(CE-MS)方法,用于测定饱和脂肪酸(FAs),该方法使用与阴离子 FA 形成单价配合物的双阳离子离子对试剂。在 pH 10 下,使用含有 40%乙腈修饰剂的甲酸铵缓冲液,通过优化各种参数,在 CE 中以正极性模式分离 21 种阴离子 FA。该方法显示出良好的分离效率,但对短链脂肪酸的方法灵敏度相当低,导致即使在负 ESI-MS 检测中乙酸和丙酸的浓度达到 100mgL 时也无法检测到。在所测试的四种双阳离子离子对试剂中,在 CE 分离过程中通过鞘液离子源注入的 N,N'-二丁基 1,1'-戊二基二吡咯烷是提高灵敏度的最佳试剂,并且与阴离子 FA 形成有利于正离子 ESI-MS 检测的配合物。单价配合物显示出改进的离子化效率,提供了 15 种 FA 的检测限(LOD),范围从 0.13 到 2.88μg/mL,线性良好(R>0.99),直到 150μg/mL。与负检测结果相比,该方法对短链和中链脂肪酸的检测效果显著。优化后的 CE-配对离子电喷雾(PIESI)-MS 方法用于奶酪和咖啡中 FA 的测定,预处理简单。该方法可扩展用于分析不饱和脂肪酸的灵敏分析。