Suppr超能文献

经导管主动脉瓣植入术患者的4D CT血管造影中主动脉瓣环的动力学

Dynamics of the aortic annulus in 4D CT angiography for transcatheter aortic valve implantation patients.

作者信息

Elattar Mustafa A, Vink Leon W, van Mourik Martijn S, Baan Jan, vanBavel Ed T, Planken R Nils, Marquering Henk A

机构信息

Department of Biomedical Engineering and Physics, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands.

Department of Heart Center, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands.

出版信息

PLoS One. 2017 Sep 8;12(9):e0184133. doi: 10.1371/journal.pone.0184133. eCollection 2017.

Abstract

BACKGROUND

Transcatheter aortic valve implantation (TAVI) is a well-established treatment for patients with severe aortic valve stenosis. This procedure requires pre-operative planning by assessment of aortic dimensions on CT Angiography (CTA). It is well-known that the aortic root dimensions vary over the heart cycle. However, sizing is commonly performed at either mid-systole or end-diastole only, which has resulted in an inadequate understanding of its full dynamic behavior.

STUDY GOAL

We studied the variation in annulus measurements during the cardiac cycle and determined if this variation is dependent on the amount of calcification at the annulus.

METHODS

We measured and compared aortic root annular dimensions and calcium volume in CTA acquisitions at 10 cardiac cycle phases in 51 aortic stenosis patients. Sub-group analysis was performed based on the volume of calcium by splitting the population into mildly and severely calcified valves subgroups.

RESULTS

For most annulus measurements, the largest differences were found between 10% and 70 to 80% cardiac cycle phases. Mean difference (±standard deviation) in annular minimum diameter, maximum diameter, area, and aspect ratio between mid-systole and end-diastole phases were 1.0 ± 0.29 mm (p = 0.065), 0.30 ± 0.24 mm (p = 0.7), 24.1 ± 7.6 mm2 (p < 0.001), and 0.041 ± 0.012 (p = 0.039) respectively. Calcium volume measurements varied strongly during the cardiac cycle. The dynamic annulus area was behaving differently between mildly and severely calcified subgroups (p = 0.02). Furthermore, patients with severe aortic calcification were associated with larger annulus diameters.

CONCLUSION

There is a significant variation of annulus area and calcium volume measurement during the cardiac cycle. In our measurements, only the dynamic variation of the annulus area is dependent on the severity of the aortic calcification. For TAVI candidates, the annulus area is significantly larger in mid-systole compared to end-diastole.

摘要

背景

经导管主动脉瓣植入术(TAVI)是治疗重度主动脉瓣狭窄患者的成熟疗法。该手术需要通过CT血管造影(CTA)评估主动脉尺寸进行术前规划。众所周知,主动脉根部尺寸在心动周期中会发生变化。然而,尺寸测量通常仅在收缩中期或舒张末期进行,这导致对其完整动态行为的理解不足。

研究目标

我们研究了心动周期中环周测量值的变化,并确定这种变化是否取决于瓣环钙化程度。

方法

我们在51例主动脉瓣狭窄患者的CTA采集中,测量并比较了10个心动周期阶段的主动脉根部环周尺寸和钙体积。根据钙体积将人群分为轻度和重度钙化瓣膜亚组进行亚组分析。

结果

对于大多数环周测量,最大差异出现在心动周期的10%与70%至80%阶段之间。收缩中期和舒张末期之间环周最小直径、最大直径、面积和纵横比的平均差异(±标准差)分别为1.0±0.29毫米(p = 0.065)、0.30±0.24毫米(p = 0.7)、24.1±7.6平方毫米(p < 0.001)和0.041±0.012(p = 0.039)。钙体积测量在心动周期中变化很大。轻度和重度钙化亚组之间动态环周面积表现不同(p = 0.02)。此外重度主动脉钙化患者的瓣环直径更大。

结论

心动周期中环周面积和钙体积测量存在显著变化。在我们的测量中,只有环周面积的动态变化取决于主动脉钙化的严重程度。对于TAVI候选者,收缩中期的瓣环面积比舒张末期显著更大。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/9af5/5590871/00fee11069b4/pone.0184133.g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验