Suppr超能文献

髋关节置换术的骨水泥碎片导致股深动脉假性动脉瘤。

Cement fragment from hip arthroplasty causing deep femoral artery pseudoaneurysm.

作者信息

Gorospe Luis, Tobío-Calo Ricardo, Rodríguez-Díaz Ricardo, Gómez-Barbosa Carol Fernanda, García Gómez-Muriel Isabel, García-Latorre Raquel

机构信息

1 Department of Radiology, Ramón y Cajal University Hospital, Madrid, Spain.

2 Department of Radiology, La Milagrosa Hospital, Madrid, Spain.

出版信息

Asian Cardiovasc Thorac Ann. 2017 Nov;25(9):633-634. doi: 10.1177/0218492317732251. Epub 2017 Sep 14.

Abstract

An 81-year-old woman who had undergone total hip arthroplasty 12 years earlier presented with a painful spontaneous hematoma in the proximal left thigh. A left hip radiograph showed a displaced cement fragment from the acetabular component of the hip prosthesis. Computed tomography confirmed an extruded cement fragment causing a large pseudoaneurysm of the deep femoral artery. The patient underwent successful percutaneous embolization of the pseudoaneurysm with coils.

摘要

一名12年前接受过全髋关节置换术的81岁女性,出现左大腿近端疼痛性自发性血肿。左髋部X线片显示髋关节假体髋臼部件有移位的骨水泥碎片。计算机断层扫描证实有一枚挤出的骨水泥碎片导致股深动脉形成一个大的假性动脉瘤。该患者接受了用弹簧圈对假性动脉瘤进行的成功经皮栓塞治疗。