Suppr超能文献

利用化学标记结合黑磷辅助激光解吸/电离飞行时间质谱法快速灵敏地测定血清葡萄糖。

Rapid and sensitive serum glucose determination using chemical labeling coupled with black phosphorus-assisted laser desorption/ionization time-of-flight mass spectrometry.

机构信息

Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), Department of Chemistry, Wuhan University, Wuhan, Hubei 430072, People's Republic of China.

Department of Pathology, Hubei Cancer Hospital, Wuhan, Hubei 430079, People's Republic of China.

出版信息

Talanta. 2018 Jan 1;176:344-349. doi: 10.1016/j.talanta.2017.08.055. Epub 2017 Aug 16.

Abstract

Monitoring the concentration of blood glucose in patients is a key component of good medical diagnoses. Therefore, developing an accurate, rapid and sensitive strategy for monitoring blood glucose is of vital importance. We proposed a strategy for serum glucose determination combining 2-(4-boronobenzyl) isoquinolin-2-ium bromide chemical labeling with black phosphorus assisted laser desorption ionization-time of flight mass spectrometry (CL-BP/ALDI-TOF MS). The entire analytical process consisted of 1min of protein precipitation and 3min of chemical labeling in a microwave oven prior to the BP/ALDI-TOF MS analysis. The analysis can be completed in 5min with high throughput and extremely low sample consumption. Good linearity for glucose was obtained with a correlation coefficient (R) of 0.9986. The limit of detection (LOD) and limit of quantification (LOQ) were 11.5 fmol and 37.5 fmol, respectively. Satisfied reproducibility and reliability were gained by evaluation of the intra- and inter-day precisions with relative standard deviations (RSDs) less than 7.2% and relative recoveries ranging from 87.1% to 108.1%, respectively. The proposed strategy was also applied for the analysis of endogenous glucose in various serum samples and the results were consistent with those obtained using the hexokinase method in a clinical laboratory. Considering the results, the proposed CL-BP/ALDI-TOF MS strategy has proven to be reliable, fast, and sensitive for quantitative analysis of serum glucose.

摘要

监测患者的血糖浓度是良好医疗诊断的关键组成部分。因此,开发一种准确、快速和敏感的血糖监测策略至关重要。我们提出了一种结合 2-(4-硼苄基)异喹啉-2- 𬭩溴化物化学标记与黑磷辅助激光解吸电离飞行时间质谱(CL-BP/ALDI-TOF MS)的血清葡萄糖测定策略。整个分析过程包括在微波炉中进行 1 分钟的蛋白质沉淀和 3 分钟的化学标记,然后进行 BP/ALDI-TOF MS 分析。该分析可以在 5 分钟内完成,具有高通量和极低的样品消耗。葡萄糖具有良好的线性关系,相关系数(R)为 0.9986。检测限(LOD)和定量限(LOQ)分别为 11.5 fmol 和 37.5 fmol。通过评估日内和日间精密度,获得了令人满意的重现性和可靠性,相对标准偏差(RSD)小于 7.2%,相对回收率在 87.1%至 108.1%之间。所提出的策略还应用于各种血清样品中内源性葡萄糖的分析,结果与临床实验室中使用己糖激酶法获得的结果一致。考虑到这些结果,所提出的 CL-BP/ALDI-TOF MS 策略已被证明可用于血清葡萄糖的定量分析,具有可靠、快速和灵敏的特点。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验