Suppr超能文献

通过系留脑电图对小鼠自发性复发性癫痫发作进行连续监测。

Continuous Monitoring via Tethered Electroencephalography of Spontaneous Recurrent Seizures in Mice.

作者信息

Bin Na-Ryum, Song Hongmei, Wu Chiping, Lau Marcus, Sugita Shuzo, Eubanks James H, Zhang Liang

机构信息

Krembil Research Institute, University Health NetworkToronto, ON, Canada.

Department of Physiology, University of TorontoToronto, ON, Canada.

出版信息

Front Behav Neurosci. 2017 Sep 14;11:172. doi: 10.3389/fnbeh.2017.00172. eCollection 2017.

Abstract

We describe here a simple, cost-effective apparatus for continuous tethered electroencephalographic (EEG) monitoring of spontaneous recurrent seizures in mice. We used a small, low torque slip ring as an EEG commutator, mounted the slip ring onto a standard mouse cage and connected rotary wires of the slip ring directly to animal's implanted headset. Modifications were made in the cage to allow for a convenient installation of the slip ring and accommodation of animal ambient activity. We tested the apparatus for hippocampal EEG recordings in adult C57 black mice. Spontaneous recurrent seizures were induced using extended hippocampal kindling (≥95 daily stimulation). Control animals underwent similar hippocampal electrode implantations but no stimulations were given. Combined EEG and webcam monitoring were performed for 24 h daily for 5-9 consecutive days. During the monitoring periods, the animals moved and accessed water and food freely and showed no apparent restriction in ambient cage activities. Ictal-like hippocampal EEG discharges and concurrent convulsive behaviors that are characteristics of spontaneous recurrent seizures were reliably recorded in a majority of the monitoring experiments in extendedly kindled but not in control animals. However, 1-2 rotary wires were disconnected from the implanted headset in some animals after continuous recordings for ≥5 days. The key features and main limitations of our recording apparatus are discussed.

摘要

我们在此描述一种简单且经济高效的装置,用于对小鼠的自发性复发性癫痫发作进行连续的束缚式脑电图(EEG)监测。我们使用了一个小型、低扭矩滑环作为EEG换向器,将滑环安装在标准小鼠笼上,并将滑环的旋转电线直接连接到动物植入的头戴式电极上。对笼子进行了改装,以便于滑环的安装并适应动物的日常活动。我们在成年C57黑小鼠中测试了该装置用于海马EEG记录的情况。使用延长的海马点燃法(≥95次每日刺激)诱导自发性复发性癫痫发作。对照动物进行了类似的海马电极植入,但未给予刺激。每天进行24小时的EEG和网络摄像头联合监测,连续进行5 - 9天。在监测期间,动物自由活动、饮水和进食,在笼内的日常活动未表现出明显受限。在大多数延长点燃的监测实验中,可靠地记录到了类似发作期的海马EEG放电以及作为自发性复发性癫痫发作特征的同时出现的惊厥行为,而对照动物未出现。然而,在连续记录≥5天后,一些动物的1 - 2根旋转电线与植入的头戴式电极断开连接。我们讨论了记录装置的关键特性和主要局限性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/23ea/5603658/5179fe3a6baa/fnbeh-11-00172-g0001.jpg