在成人、青少年和儿童头部体模中,针对多层螺旋CT(MSCT)和牙科锥形束CT(CBCT)扫描仪,比较CT剂量指数(CTDI)和美国医学物理师协会第111号报告中的方法。

Comparison of the CTDI and AAPM report No. 111 methodology in adult, adolescent, and child head phantoms for MSCT and dental CBCT scanners.

作者信息

Li Celina L, Thakur Yogesh, Ford Nancy L

机构信息

University of British Columbia, Faculty of Science, Department of Physics and Astronomy, Vancouver, British Columbia, Canada.

Lower Mainland Medical Imaging Services, Vancouver Coastal Health Authority, Vancouver, British Columbia, Canada.

出版信息

J Med Imaging (Bellingham). 2017 Jul;4(3):031212. doi: 10.1117/1.JMI.4.3.031212. Epub 2017 Sep 29.

Abstract

This study investigates the dosimetry methodology proposed by the American Association of Physicists in Medicine (AAPM) task group 111 and compares with the computed tomography dose index (CTDI) method and the SEDENTEXCT DI method on one clinical multislice CT and two dental cone beam CT (CBCT) scanners using adult, adolescent, and child head phantoms. Following the AAPM method, the normalized (100 mAs) equilibrium doses ([Formula: see text]) for Toshiba Aquilion One MSCT computed using dose measurements from the central hole of the phantom ([Formula: see text]), the peripheral hole of the phantom, ([Formula: see text]), and by the [Formula: see text] equation ([Formula: see text]) are in the range from 20 to 25 mGy. For i-CAT Next Generation dental CBCT, the normalized [Formula: see text], [Formula: see text], [Formula: see text], and [Formula: see text] by the two SEDENTEXCT DI methods are in the range from 12 to 15 mGy. Fitting the AAPM equation is not possible for the limited scan lengths available on the CS 9300 dental CBCT. This study offers a simple CTDI-like measurement that can approximate the AAPM [Formula: see text] in clinical CBCT scanners capable of providing four or more scan lengths.

摘要

本研究调查了美国医学物理学家协会(AAPM)任务组111提出的剂量测定方法,并在一台临床多层CT和两台牙科锥形束CT(CBCT)扫描仪上,使用成人、青少年和儿童头部模型,将其与计算机断层扫描剂量指数(CTDI)方法和SEDENTEXCT DI方法进行比较。按照AAPM方法,使用模型中心孔的剂量测量值([公式:见原文])、模型外周孔的剂量测量值([公式:见原文])以及通过[公式:见原文]方程([公式:见原文])计算得出的东芝Aquilion One MSCT的归一化(100 mAs)平衡剂量([公式:见原文])在20至25 mGy范围内。对于i-CAT下一代牙科CBCT,两种SEDENTEXCT DI方法得出的归一化[公式:见原文]、[公式:见原文]、[公式:见原文]和[公式:见原文]在12至15 mGy范围内。对于CS 9300牙科CBCT上可用的有限扫描长度,无法拟合AAPM方程。本研究提供了一种类似CTDI的简单测量方法,在能够提供四个或更多扫描长度的临床CBCT扫描仪中,该方法可以近似AAPM的[公式:见原文]。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/33ec/5621782/f9c719c79704/JMI-004-031212-g003.jpg

相似文献

1
Comparison of the CTDI and AAPM report No. 111 methodology in adult, adolescent, and child head phantoms for MSCT and dental CBCT scanners.
J Med Imaging (Bellingham). 2017 Jul;4(3):031212. doi: 10.1117/1.JMI.4.3.031212. Epub 2017 Sep 29.
2
Dose measurements for dental cone-beam CT: a comparison with MSCT and panoramic imaging.
Phys Med Biol. 2014 Jun 21;59(12):3201-22. doi: 10.1088/0031-9155/59/12/3201. Epub 2014 May 27.
5
A polynomial approximation to an exponential growth function for calculating equilibrium dose in CT.
Phys Med Biol. 2020 Oct 16;65(20):20NT01. doi: 10.1088/1361-6560/abb02d.
8
Investigation of the radiation dose from cone-beam CT for image-guided radiotherapy: A comparison of methodologies.
J Appl Clin Med Phys. 2018 Jan;19(1):174-183. doi: 10.1002/acm2.12239. Epub 2017 Dec 19.
9
Comparison of radiation doses between cone beam CT and multi detector CT: TLD measurements.
Radiat Prot Dosimetry. 2008;132(3):339-45. doi: 10.1093/rpd/ncn305. Epub 2008 Dec 13.
10
Influence of cone beam CT (CBCT) scan parameters on size specific dose estimate (SSDE): a Monte Carlo study.
Phys Med Biol. 2019 May 23;64(11):115002. doi: 10.1088/1361-6560/ab0bc8.

引用本文的文献

1
A simplified low-cost phantom for image quality assessment of dental cone beam computed tomography unit.
J Med Radiat Sci. 2024 Mar;71(1):78-84. doi: 10.1002/jmrs.738. Epub 2023 Nov 15.
2
Optimization of cone beam computed tomography image quality in implant dentistry.
Clin Exp Dent Res. 2018 Nov 12;4(6):268-278. doi: 10.1002/cre2.141. eCollection 2018 Dec.

本文引用的文献

1
Quantitative performance characterization of image quality and radiation dose for a CS 9300 dental cone beam computed tomography machine.
J Med Imaging (Bellingham). 2015 Oct;2(4):044002. doi: 10.1117/1.JMI.2.4.044002. Epub 2015 Nov 18.
2
Cone beam CT for dental and maxillofacial imaging: dose matters.
Radiat Prot Dosimetry. 2015 Jul;165(1-4):156-61. doi: 10.1093/rpd/ncv057. Epub 2015 Mar 23.
3
Measuring absorbed dose for i-CAT CBCT examinations in child, adolescent and adult phantoms.
Dentomaxillofac Radiol. 2015;44(6):20150018. doi: 10.1259/dmfr.20150018. Epub 2015 Mar 18.
4
Effective dose of dental CBCT-a meta analysis of published data and additional data for nine CBCT units.
Dentomaxillofac Radiol. 2015;44(1):20140197. doi: 10.1259/dmfr.20140197.
5
Dose measurements for dental cone-beam CT: a comparison with MSCT and panoramic imaging.
Phys Med Biol. 2014 Jun 21;59(12):3201-22. doi: 10.1088/0031-9155/59/12/3201. Epub 2014 May 27.
7
Dose indices in dental cone beam CT and correlation with dose-area product.
Dentomaxillofac Radiol. 2013;42(5):20120362. doi: 10.1259/dmfr.20120362. Epub 2013 Mar 21.
9
Measurements of the dose delivered during CT exams using AAPM Task Group Report No. 111.
J Appl Clin Med Phys. 2012 Nov 8;13(6):3934. doi: 10.1120/jacmp.v13i6.3934.
10
Dose distribution for dental cone beam CT and its implication for defining a dose index.
Dentomaxillofac Radiol. 2012 Oct;41(7):583-93. doi: 10.1259/dmfr/20920453. Epub 2012 Jun 29.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验