Eur J Radiol. 2017 Oct;95:242-248. doi: 10.1016/j.ejrad.2017.08.034. Epub 2017 Aug 31.
To evaluate the influence of monoenergetic reconstructions using a spectral detector CT (SDCT) on the computer aided detection (CAD) of pulmonary artery embolism (PAE) on CT pulmonary angiography (CTPA) and CT in venous contrast phase (CTV).
A retrospective data base search identified 15 patients with CTPA and 18 patients with CTV and diagnosis of PAE. For these patients, monoenergetic (monoE) images at different energy levels or with a fixed attenuation in the pulmonary artery were generated and independently analyzed using a commercially available computer aided detection (CAD) tool. Attenuation in the pulmonary artery and in the embolus was measured.
For CTPA and CTV, in monoenergetic images the difference in attenuation between vessel and embolus was significantly higher than in conventional images. In CTPA the detection rate was highest in the >500 HU monoE images with 67,9% detected emboli and 93,3% of patients correctly identified as having PAE. At the same time the false positive rate could be significantly reduced by using monoE images compared to conventional images. Detection rates for CTV were lower than in CTPA but were raised significantly by monoE reconstructions.
The combination of SDCT and CAD improves the diagnostic accuracy of CAD and enables CAD interpretation of CTV.
评估能谱探测器 CT(SDCT)单能量重建对 CT 肺动脉造影(CTPA)和 CT 静脉对比期(CTV)中肺动脉栓塞(PAE)计算机辅助检测(CAD)的影响。
回顾性数据库搜索共纳入 15 例 CTPA 患者和 18 例 CTV 患者及 PAE 诊断患者。对这些患者,采用市售的计算机辅助检测(CAD)工具生成不同能量水平的单能量(monoE)图像或肺动脉固定衰减值图像,并进行独立分析。测量肺动脉和栓子的衰减值。
对于 CTPA 和 CTV,在单能量图像中,血管和栓子之间的衰减差异明显高于常规图像。在 CTPA 中,>500HU 单能量图像的检测率最高,检出 67.9%的栓子,93.3%的患者正确识别为 PAE。同时,与常规图像相比,单能量图像可显著降低假阳性率。CTV 的检测率低于 CTPA,但单能量重建可显著提高检测率。
SDCT 和 CAD 的结合提高了 CAD 的诊断准确性,并使 CAD 能够解读 CTV。