Suppr超能文献

Precision and Accuracy in the Determination of Sulfur Oxides, Fluoride, and Spherical Aluminosilicate Fly Ash Particles in Project MOHAVE.

作者信息

Eatough Norman L, Eatough Michele, Eatough Delbert J, Joseph Jyothi M, Caka Fern M

机构信息

a Department of Chemistry , California Polytechnic State University , San Luis Obispo , California.

b Department of Chemistry and Biochemistry Brigham Young University , Provo , Utah.

出版信息

J Air Waste Manag Assoc. 1997 Mar;47(3):455-467. doi: 10.1080/10473289.1997.10464440.

Abstract

The precision and accuracy of the determination of particu-late sulfate and fluoride, and gas phase SO and HF are estimated from the results obtained from collocated replicate samples and from collocated comparison samples for high-and low-volume filter pack and annular diffusion denuder samplers. The results of replicate analysis of collocated samples and replicate analyses of a given sample for the determination of spherical aluminosilicate fly ash particles have also been compared. Each of these species is being used in the chemical mass balance source apportionment of sulfur oxides in the Grand Canyon region as part of Project MOHAVE, and the precision and accuracy analyses given in this paper provide input to that analysis. The precision of the various measurements reported here is ±1.8 nmol/m and ±2.5 nmol/m for the determination of SO and sulfate, respectively, with an annular denuder. The precision is ±0.5 nmol/m and ±2.0 nmol/m for the determination of the same species with a high-volume or low-volume filter pack. The precision for the determination of the sum of HF(g) and fine particulate fluoride is ±0.3 nmol/m. The precision for the determination of aluminosilicate fly ash particles is ±100 particles/m. At high concentrations of the various species, reproducibility of the various measurements is ±10% to ±14% of the measured concentration. The concentrations of sulfate determined using filter pack samplers are frequently higher than those determined using diffusion denuder sampling systems. The magnitude of the difference (e.g., 2-10 nmol sulfate/m) is small, but important relative to the precision of the data and the concentrations of particulate sul-fate present (typically 5-20 nmol sulfate/m). The concentrations of SO(g) determined using a high-volume cascade impactor filter pack sampler are correspondingly lower than those obtained with diffusion denuder samplers. The concentrations of SO (SO(g) plus particulate sulfate) determined using the two samplers during Project MOHAVE at the Spirit Mountain, NV, and Hopi Point, AZ, sampling sites were in agreement. However, for samples collected at Painted Desert, AZ, and Meadview, AZ, the concentrations of SO and SO(g) determined with a high-volume cascade impactor filter pack sampler were frequently lower than those determined using a diffusion denuder sampling system. These two sites had very low ambient relative humidity, an average of 25%. Possible causes of observed differences in the SO(g) and sulfate results obtained from different types of samplers are given.

摘要

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验