Suppr超能文献

Technique developments and performance analysis of chirped-probe-pulse femtosecond coherent anti-Stokes Raman scattering combustion thermometry.

作者信息

Thomas Levi M, Satija Aman, Lucht Robert P

出版信息

Appl Opt. 2017 Nov 1;56(31):8797-8810. doi: 10.1364/AO.56.008797.

Abstract

This work characterizes the state of the art in the analysis of high-repetition-rate, ultrafast combustion thermometry using chirped-probe-pulse femtosecond coherent anti-Stokes Raman scattering (CPP fs-CARS). Several key aspects of the CARS spectroscopy system are described, including: (1) the ultrafast laser source, (2) use of the frequency-doubled idler versus signal from the optical parametric amplifier, (3) the geometry constraints for phase matching, and (4) spectral fitting for single-shot temperature measurements. A frequency-dependent instrument response function (IRF) for the detection system was modeled as a variable-width Gaussian and implemented through a frequency convolution of synthetic spectra. Proper accounting of the IRF increased spectral fitting performance in the high-frequency region where signal oscillations are weaker and narrower. Aggregated data from 25 system performance assessments taken over four months yielded accuracy and precision of 2.7% and ±3.5% for flame temperatures, and 9.9% and ±6.1% at room temperature, using the commonly reported method. A new processing technique, based on the statistical method of maximum likelihood, was implemented for turbulent flames where strong fluctuations in expected temperatures necessitate use of multiple temperature calibrations. Results from multiple sets of laser parameters are combined to generate an error-weighted temperature from the top-performing calibrations. A testing procedure was designed to characterize system performance when the range of expected temperatures is unknown, simulating the random temperature field of a highly turbulent flame. Accuracy error of the CPP fs-CARS system increased in this more-stressing test at all temperatures, but precision was significantly affected only at room temperature. System stability is characterized, and the contribution from shot-to-shot laser fluctuations on measurement precision is quantified. Finally, the near-adiabatic and steady assumptions for the Hencken burner calibration flame are examined in an axial scan; significant deviations from ideal behavior were observed only at heights of more than four diameters above the burner surface.

摘要

相似文献

5
One-dimensional single-shot thermometry in flames using femtosecond-CARS line imaging.
Opt Lett. 2011 Nov 1;36(21):4182-4. doi: 10.1364/OL.36.004182.
6
Gas-phase single-shot thermometry at 1 kHz using fs-CARS spectroscopy.
Opt Lett. 2009 Dec 15;34(24):3857-9. doi: 10.1364/OL.34.003857.
9
Coherent Anti-Stokes Raman Scattering Measurements of Time and Length Scales of Temperature Fluctuations in a Turbulent Flame.
Appl Spectrosc. 2023 May;77(5):482-490. doi: 10.1177/00037028231160797. Epub 2023 Feb 24.
10
Pure-rotational H thermometry by ultrabroadband coherent anti-Stokes Raman spectroscopy.
J Chem Phys. 2017 Jun 14;146(22):224202. doi: 10.1063/1.4984083.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验