Suppr超能文献

股骨头灌注参数的区域变化评估:一项3-T动态对比增强MRI初步研究。

Assessment of the zonal variation of perfusion parameters in the femoral head: a 3-T dynamic contrast-enhanced MRI pilot study.

作者信息

Budzik Jean-François, Lefebvre Guillaume, Behal Hélène, Verclytte Sébastien, Hardouin Pierre, Teixeira Pedro, Cotten Anne

机构信息

Imaging Department, Lille Catholic Hospitals, Lille Catholic University, F-59000, Lille, France.

Lille University, Littoral Côte d'Opale University, EA 4490, PMOI, Physiopathologie des Maladies Osseuses Inflammatoires, F-59000, Lille, France.

出版信息

Skeletal Radiol. 2018 Feb;47(2):261-270. doi: 10.1007/s00256-017-2802-7. Epub 2017 Nov 15.

Abstract

OBJECTIVE

The objective was to describe MR perfusion characteristics of the femoral head, with a focus on the subchondral bone.

MATERIALS AND METHODS

This prospective monocentric study was approved by our local Ethics Committee. Written informed consent was obtained from all subjects. Dynamic contrast-enhanced MRI of the right hip was performed in 59 adults with suspected spondyloarthritis (32 women, 28 men). Mean age was 37.5 (±12.5) years. Regions of interest were drawn in the femoral head epiphysis, in the subchondral areas the most exposed to mechanical load (superolateral, anterosuperior, and posterior zones) and in areas less exposed to mechanical load (inferior subchondral zone and center of the femoral head). Semi-quantitative and pharmacokinetic parameters were calculated using the Tofts model. Statistical analysis was performed with a linear mixed model to compare the perfusion parameters in the different femoral head zones.

RESULTS

Extravascular extracellular volume and area under the curve were lower in the superolateral zone than in the inferior zone (p = 0.0135 and p < 0.0001 respectively) and the central zone (p = 0.007 and p = 0.0134 respectively). Extravascular extracellular volume and rate constant were lower in the anterosuperior zone than in the inferior zones (p = 0.011 and p = 0.029). In the anterosuperior zone, extravascular extracellular volume was lower, and time to peak was higher than in the central zones (p = 0.0056 and p = 0.0013 respectively). No significant differences were found for any values between other paired zones.

CONCLUSION

The perfusion of femoral head subchondral bone assessed with dynamic contrast-enhanced magnetic resonance imaging is not homogeneous: the areas exposed to more mechanical loading are less perfused.

摘要

目的

描述股骨头的磁共振灌注特征,重点关注软骨下骨。

材料与方法

本前瞻性单中心研究获当地伦理委员会批准。所有受试者均签署书面知情同意书。对59例疑似脊柱关节炎的成年人(32例女性,28例男性)进行了右髋动态对比增强磁共振成像检查。平均年龄为37.5(±12.5)岁。在股骨头骨骺、最易受机械负荷的软骨下区域(上外侧、前上和后区)以及受机械负荷较小的区域(软骨下下区和股骨头中心)绘制感兴趣区。使用Tofts模型计算半定量和药代动力学参数。采用线性混合模型进行统计分析,以比较不同股骨头区域的灌注参数。

结果

上外侧区的血管外细胞外容积和曲线下面积低于下区(分别为p = 0.0135和p < 0.0001)和中央区(分别为p = 0.007和p = 0.0134)。前上区的血管外细胞外容积和速率常数低于下区(p = 0.011和p = 0.029)。在前上区,血管外细胞外容积较低,达峰时间高于中央区(分别为p = 0.0056和p = 0.0013)。其他配对区域之间的任何值均未发现显著差异。

结论

动态对比增强磁共振成像评估的股骨头软骨下骨灌注不均匀:机械负荷较大的区域灌注较少。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验