Mohsin Abdul Habeeb Bin, Reddy Varalakshmi, Kumar Praveen, Raj Jeevan, Babu Siva Santosh
Department of Prosthodontics, Sri Sai College of Dental Surgery, Vikarabad, India.
Department of Prosthodontics, MNR Dental College and Hospital, Sangareddy, India.
Pan Afr Med J. 2017 Jul 10;27:185. doi: 10.11604/pamj.2017.27.185.9098. eCollection 2017.
The aim of this study was to evaluate & compare the wetting ability of five saliva substitutes & distilled water on heat-polymerized acrylic resin. Contact angle of the saliva substitute on denture base can be taken as an indicator of wettability. Good wetting of heat-polymerized acrylic resin is critical for optimum retention of complete dentures.
Two hundred & forty samples of heat-polymerized acrylic resin were fabricated using conventional method. 240 samples divided into 6 groups with 40 samples in each group. Advancing & Receding contact angles were measured using Contact Angle Goniometer & DSA4 software analysis.
Anova test was carried out to test the significance in difference of contact angle values in the six groups. The mean of advancing angle values & mean of receding angle values of all the six groups has shown statistically significant difference between the groups. The mean of angle of hysteresis values of all the six groups are statistically not significant between the groups. A multiple comparison using Bonferroni's test was carried out to verify the significance of difference between the contact angles in a pair of groups. Statistically significant difference was seen when Aqwet (Group II) was compared to Distilled water (Group I), Wet Mouth (Group III), E-Saliva (Group IV), Biotene (Group V), and Moi-Stir (Group VI).
The contact angles of five saliva substitutes and distilled water were measured and compared. Group II (AQWET) has the lowest advancing and receding contact angle values and the highest angle of hysteresis on heat-polymerized acrylic resin. Based on contact angle values, Group II (AQWET) has the best wetting ability on heat-cured acrylic resins. The ability of saliva to wet the denture surface is one of the most important properties for complete denture retention in dry mouth cases.
本研究旨在评估并比较五种唾液替代品及蒸馏水对热聚合丙烯酸树脂的润湿能力。义齿基托上唾液替代品的接触角可作为润湿性的指标。热聚合丙烯酸树脂的良好润湿对于全口义齿的最佳固位至关重要。
采用常规方法制作240个热聚合丙烯酸树脂样本。将240个样本分为6组,每组40个样本。使用接触角测量仪和DSA4软件分析测量前进接触角和后退接触角。
进行方差分析以检验六组接触角值差异的显著性。所有六组的前进角值均值和后退角值均值在组间显示出统计学上的显著差异。所有六组的滞后角值均值在组间无统计学显著性。使用邦费罗尼检验进行多重比较,以验证两组间接触角差异的显著性。当将Aqwet(第二组)与蒸馏水(第一组)、湿口(第三组)、E-唾液(第四组)、保丽净(第五组)和Moi-Stir(第六组)进行比较时,观察到统计学上的显著差异。
测量并比较了五种唾液替代品和蒸馏水的接触角。第二组(Aqwet)在热聚合丙烯酸树脂上具有最低的前进和后退接触角值以及最高的滞后角。基于接触角值,第二组(Aqwet)在热固化丙烯酸树脂上具有最佳的润湿能力。在口干病例中,唾液润湿义齿表面的能力是全口义齿固位最重要的特性之一。