Plasma and serum are often used interchangeably for therapeutic drug monitoring (TDM) purposes, and concentrations of some drugs are reported to be lower in serum than in plasma when collected into blood collection tubes containing a gel separator. TDM is recommended for clozapine, although few studies have compared concentrations between plasma and serum. Therefore, we investigated the comparability of dipotassium ethylenediaminetetraacetic acid human plasma and serum from blood collection tubes containing a gel separator for the measurement of clozapine and norclozapine.
Whole blood from patients (N = 93) prescribed clozapine was collected into a polypropylene Vacuette dipotassium ethylenediaminetetraacetic acid-containing blood collection tube (Greiner Bio-One), and a polypropylene Vacuette serum separator blood collection tube (Greiner Bio-One) containing a clotting activator (silica particles) and a polymer gel.
Mean clozapine concentrations were significantly (P ≤ 0.05) lower in serum (0.37 mg/L) than in plasma (0.39 mg/L), as were concentrations of norclozapine (0.17 and 0.18 mg/L, respectively). Bland-Altman plots indicated mean serum clozapine and norclozapine were 0.018 mg/L (5.3%) and 0.004 mg/L (3.6%), respectively, lower in serum than plasma.
Despite the finding that clozapine and norclozapine were significantly higher in plasma than in serum when obtained from blood collected into Vacuette serum separator collection tubes, this difference is insignificant in the clinical interpretation of clozapine and norclozapine TDM results.
血浆和血清在治疗药物监测(TDM)中常被互换使用,据报道,当采集到含有凝胶分离器的采血管中时,某些药物在血清中的浓度低于血浆中的浓度。虽然推荐对氯氮平进行TDM,但很少有研究比较血浆和血清中氯氮平的浓度。因此,我们研究了含凝胶分离器的采血管中乙二胺四乙酸二钾人血浆和血清在测定氯氮平和去甲氯氮平时的可比性。
将开具氯氮平处方的患者(N = 93)的全血采集到含乙二胺四乙酸二钾的聚丙烯真空采血管(Greiner Bio-One)以及含有凝血激活剂(二氧化硅颗粒)和聚合物凝胶的聚丙烯真空血清分离采血管(Greiner Bio-One)中。
血清中氯氮平的平均浓度(0.37 mg/L)显著低于血浆(0.39 mg/L)(P≤0.05),去甲氯氮平的浓度(分别为0.17和0.18 mg/L)也是如此。布兰德-奥特曼图表明,血清中氯氮平和去甲氯氮平的平均浓度分别比血浆低0.018 mg/L(5.3%)和0.004 mg/L(3.6%)。
尽管发现从真空血清分离采血管采集的血液中,氯氮平和去甲氯氮平在血浆中的浓度显著高于血清,但这种差异在氯氮平和去甲氯氮平TDM结果的临床解读中并不显著。