Suppr超能文献

使用不同美学材料的CAD/CAM桩核:抗折性和粘结强度。

CAD/CAM post-and-core using different esthetic materials: Fracture resistance and bond strengths.

作者信息

Falcão Spina Denis Roberto, Goulart da Costa Rogério, Farias Isabelli Carolini, da Cunha Leonardo Gonçalves, Ritter André Vicente, Gonzaga Carla Castiglia, Correr Giselle Maria

机构信息

Department of Dental Prosthesis, Federal Institute for Science and Technology of Paraná Curitiba, PR, Brazil.

Graduate Program in Clinical Dentistry, School of Dentistry, University of Positivo, Curitiba, Paraná, Brazil.

出版信息

Am J Dent. 2017 Dec;30(6):299-304.

Abstract

PURPOSE

To evaluate the fracture resistance (FR), and push-out bond strengths (BS) of custom-made CAD/CAM post-and-cores manufactured with different esthetic materials.

METHODS

90 single-rooted extracted teeth were selected, endodontically treated and prepared to receive the posts. The specimens were randomly divided into three equal groups according to the material: hybrid ceramic Vita Enamic (HC); nano-ceramic resin composite Lava Ultimate (RC); and experimental epoxy-resin reinforced by glass-fiber (FG). The post-and-cores were manufactured using CAD/CAM and cemented using a self-adhesive resin cement (Rely X Unicem2). A subgroup of 30 specimens (n=10) was subjected to fatigue (1,000,000 cycles at 5 Hz) and then to the FR test. Another subgroup with 60 specimens was submitted to the BS test, with and without fatigue. Data were submitted to analysis of variance (FR - one-way ANOVA; BS - two-way ANOVA) and Tukey's test (α= 0.05).

RESULTS

The FR values (mean±SD, in Newtons) were 414.5±83.9 (HC), 621.3±100.3 (RC), and 407.6±109.0 (FG), with RC showing significantly higher FR values (P< 0.05). For BS, there was no statistically significant difference among the materials, with and without fatigue (P> 0.05). The type of material used to obtain the CAD/CAM-customized post-and-cores had a significant effect on the FR, but not on the BS of the specimens. Fatigue did not influence the BS for the tested materials.

CLINICAL SIGNIFICANCE

CAD/CAM custom-made esthetic post-and-cores showed good performance relative to fracture resistance and bond strength to root canal dentin walls. The CAD/CAM materials tested could be used as an alternative to restore wide flared root canals in esthetically compromised teeth.

摘要

目的

评估采用不同美学材料制作的定制式计算机辅助设计/计算机辅助制造(CAD/CAM)桩核的抗折强度(FR)和推出粘结强度(BS)。

方法

选取90颗单根离体牙,进行根管治疗并预备以容纳桩。根据材料将标本随机分为三组,每组数量相等:混合陶瓷Vita Enamic(HC);纳米陶瓷树脂复合材料Lava Ultimate(RC);以及玻璃纤维增强实验性环氧树脂(FG)。使用CAD/CAM制作桩核,并用自粘结树脂水门汀(Rely X Unicem2)粘结。30个标本的亚组(n = 10)先进行疲劳测试(5赫兹下1,000,000次循环),然后进行FR测试。另一个包含60个标本的亚组进行有无疲劳情况下的BS测试。数据进行方差分析(FR - 单因素方差分析;BS - 双因素方差分析)和Tukey检验(α = 0.05)。

结果

FR值(均值±标准差,单位为牛顿)分别为414.5±83.9(HC)、621.3±100.3(RC)和407.6±109.0(FG),其中RC显示出显著更高的FR值(P < 0.05)。对于BS,有无疲劳情况下材料之间均无统计学显著差异(P > 0.05)。用于获取CAD/CAM定制桩核的材料类型对标本的FR有显著影响,但对BS无显著影响。疲劳对测试材料的BS无影响。

临床意义

CAD/CAM定制美学桩核在抗折强度和与根管牙本质壁的粘结强度方面表现良好。所测试的CAD/CAM材料可作为修复美观受损牙齿中宽大喇叭口状根管的替代方法。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验