This paper studies the removal of crystal violet (CV) dye by electrocoagulation (EC) process using bipolar iron electrodes. Numerous operating parameters such as initial CV solution concentration, speed of agitation, number of electrodes, type and quantity of supporting electrolyte, temperature- and initial pH were investigated. A complete removal of 10 mg/L CV was achieved within 10 min at pH 7, 0.5 g NaCl, 1 LCV, 750 rpm, 9 sheets, 17.36 mAcm, and 25 °C. The performed energy-dispersive X-ray spectroscopy (EDAX), scanning electron microscopy (SEM) and Fourier transform infrared spectroscopy (FTIR) analyses confirmed the adsorption of CV onto the insoluble iron hydroxide flocs. Amongst the studied adsorption isotherms models, Langmuir and Dubinin-Radushkevich were the most applicable. The kinetic of adsorption of CV onto flocs during the EC operation was studied using the pseudo-first-order, pseudo-second-order, and intraparticulate diffusion models, with results affirming that the adsorption process proceeded according to the pseudo-second-order model. The study of thermodynamic parameters (ΔG, ΔH, and ΔS,) of the CV removal at different temperatures reflected the feasibility of the spontaneous randomness of endothermic adsorption, especially at lower temperatures. The multiple regression equation of the removal of CV by EC technique under the different studied conditions was predicted.
本文研究了使用双极铁电极通过电凝聚(EC)工艺去除结晶紫(CV)染料的方法。研究了许多操作参数,如初始CV溶液浓度、搅拌速度、电极数量、支持电解质的类型和数量、温度以及初始pH值。在pH值为7、0.5 g氯化钠、1 L CV、750转/分钟、9片电极、17.36 mA/cm²和25°C的条件下,10分钟内可实现对10 mg/L CV的完全去除。所进行的能量色散X射线光谱(EDAX)、扫描电子显微镜(SEM)和傅里叶变换红外光谱(FTIR)分析证实了CV吸附在不溶性氢氧化铁絮凝物上。在所研究的吸附等温线模型中,Langmuir模型和Dubinin-Radushkevich模型最为适用。使用准一级、准二级和颗粒内扩散模型研究了EC操作过程中CV在絮凝物上的吸附动力学,结果表明吸附过程符合准二级模型。对不同温度下CV去除的热力学参数(ΔG、ΔH和ΔS)的研究反映了吸热吸附自发随机性的可行性,尤其是在较低温度下。预测了在不同研究条件下EC技术去除CV的多元回归方程。