Illinois Fire Service Institute, University of Illinois at Urbana-Champaign, Champaign, IL, USA.
Dept. of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL, USA.
Appl Ergon. 2018 May;69:112-119. doi: 10.1016/j.apergo.2018.01.006.
Slips, trips and falls are leading causes of fireground injuries. A functional balance test (FBT) was used to investigate the effects of self-contained breathing apparatus (SCBA) size and design, plus firefighting work cycle. During the FBT, subjects walked along a narrow platform and turned in defined spaces, with and without an overhead obstacle. Thirty firefighters wore three varying-sized standard SCBAs and a low-profile prototype SCBA during three simulated firefighting work/rest cycles. Firefighters were tested pre- and post-firefighting activity (one bout, two bouts with a 5-min break, or back-to-back bouts with no break). Subjects committed more errors and required longer completion times with larger SCBAs. Use of the prototype SCBA lead to lower times and fewer errors. Performing a second bout of firefighting increased completion time. Firefighters need to consider how SCBA and amount of physical activity on the fireground may influence balance in order to reduce the risk of injury.
滑倒、绊倒和跌倒是导致火场受伤的主要原因。功能性平衡测试(FBT)用于研究自给式呼吸装置(SCBA)的大小和设计以及消防工作周期的影响。在 FBT 中,受试者沿着狭窄的平台行走,并在有和没有头顶障碍物的情况下在规定的空间内转弯。30 名消防员在三个模拟消防工作/休息周期中穿着三种不同尺寸的标准 SCBA 和一种低轮廓原型 SCBA。在消防活动前后(一轮、两轮,中间休息 5 分钟,或两轮无休息)对消防员进行测试。消防员使用较大的 SCBA 会犯更多错误,完成时间更长。使用原型 SCBA 可减少用时和错误。进行第二轮消防工作会增加完成时间。消防员需要考虑 SCBA 和火场上体力活动的多少可能会如何影响平衡,以降低受伤风险。