Suppr超能文献

101 枚 BeGraft 支架移植物作为开窗腔内修复术的支撑移植物的 1 年结果。

One Year Outcomes of 101 BeGraft Stent Grafts used as Bridging Stents in Fenestrated Endovascular Repairs.

机构信息

Department of Vascular Surgery, Hôpital Cardiologique, CHRU Lille, France.

Department of Aortic and Vascular Surgery, Aortic Centre, Hôpital Marie Lannelongue, Le Plessis-Robinson, France.

出版信息

Eur J Vasc Endovasc Surg. 2018 Apr;55(4):504-510. doi: 10.1016/j.ejvs.2018.01.023. Epub 2018 Mar 1.

Abstract

OBJECTIVES

To evaluate the outcomes of the second generation BeGraft balloon expandable covered stent Graft System (Bentley InnoMed, Hechingen, Germany) implanted as bridging stent grafts during fenestrated endovascular aortic repair (FEVAR) of complex aneurysms.

DESIGN

This was a single centre prospective study including all consecutive patients treated by FEVAR performed with second generation BeGraft stent grafts as bridging stents.

METHODS

Demographics of patients, diameter and length of the bridging stent grafts, technical success, re-interventions, occlusions, post-operative events, and imaging (Cone Beam CT and/or CT scan, and contrast enhanced ultrasound) were prospectively collected in an electronic database. Duplex ultrasound was performed before discharge and at 6 month follow-up. At 1 year, patients were evaluated clinically and by imaging (CT and ultrasound).

RESULTS

Between November 2015 and September 2016, 39 consecutive patients (one woman) were treated with custom made fenestrated endografts (2-5 fenestrations) for complex aneurysms or type 1 endoleak after EVAR, using a variety of bridging stents including the BeGraft. All 101 BeGraft stent grafts were successfully delivered and deployed. There was no in hospital mortality. Early fenestration patency rate was 99% (96/97); the sole target vessel post-operative occlusion was secondary to a dissection of the renal artery distal to the stent. Complementary stenting was unsuccessful in recovering renal artery patency; bilateral renal stent occlusion was observed in the same patient on a CT scan performed 2 months after the procedure. He required post-operative dialysis. No additional renal impairment was observed. During follow-up (median 13 months [11-15]), all fenestrations stented with BeGraft stent grafts remained patent (95/97, 98%). One type 1b endoleak was detected and treated (2.6%).

CONCLUSIONS

BeGraft stent grafts used as bridging stents during FEVAR are associated with favourable outcomes at 1 year follow-up. Long-term follow-up is required to confirm these promising results.

摘要

目的

评估第二代 BeGraft 球囊扩张覆膜支架系统(德国宾廷格医疗,海兴根)作为腔内修复术(EVAR)治疗复杂动脉瘤的分支支架移植物的效果。

设计

这是一项单中心前瞻性研究,纳入了所有接受第二代 BeGraft 支架移植物作为分支支架的 EVAR 治疗的连续患者。

方法

在电子数据库中前瞻性收集患者的人口统计学数据、分支支架的直径和长度、技术成功率、再干预、闭塞、术后事件以及影像学(锥形束 CT 和/或 CT 扫描和对比增强超声)。在出院前和 6 个月随访时进行双功能超声检查。在 1 年时,通过影像学(CT 和超声)评估患者的临床和血管状况。

结果

2015 年 11 月至 2016 年 9 月,连续 39 例患者(1 例女性)因复杂动脉瘤或 EVAR 后 1 型内漏而行定制的分支血管内移植物治疗,使用了多种分支支架,包括 BeGraft。所有 101 个 BeGraft 支架均成功输送和展开。无院内死亡。早期开窗通畅率为 99%(96/97);唯一的靶血管术后闭塞是由于支架远端的肾动脉夹层。对肾动脉进行补充支架置入术未能恢复其通畅性;在术后 2 个月的 CT 扫描中,同一患者观察到双侧肾支架闭塞。该患者需要术后透析。未观察到其他肾脏损害。在随访期间(中位随访时间 13 个月[11-15]),所有用 BeGraft 支架移植物支架的开窗均保持通畅(95/97,98%)。发现并治疗了 1 例 1b 型内漏(2.6%)。

结论

在 FEVAR 中作为分支支架的 BeGraft 支架移植物在 1 年随访时具有良好的效果。需要长期随访以确认这些有前途的结果。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验