Suppr超能文献

评估低能量微波技术(Termatrac)在模拟石膏板系统中检测西方干木白蚁的能力。

Evaluation of Low-Energy Microwaves Technology (Termatrac) for Detecting Western Drywood Termite in a Simulated Drywall System.

作者信息

Taravati Siavash

机构信息

University of California, Cooperative Extension-Los Angeles County, Alhambra, CA.

出版信息

J Econ Entomol. 2018 May 28;111(3):1323-1329. doi: 10.1093/jee/toy063.

Abstract

Detecting drywood termites in structures is very challenging. Microwaves technology (Termatrac T3i) is a nondestructive method for detecting drywood termites in structures. Termatrac device and its mobile application provide a bar as well as a line graph when detecting insect movements, but interpreting these graphs is very subjective. In this paper, Termatrac's output signal is quantified using a new method to study the effect of wall layers, wood type, and termite density on signal strength measured as area under curve in a simulated drywall system in laboratory. Two experiments were conducted on Termatrac T3i at its maximum sensitivity (Gain: 10). In experiment I, HEXBUG Nano was used as a source of movement/vibration and two wood types were used in which the wall layers significantly predicted signal strength, but wood type did not. In experiment II, two different densities of live western drywood termites, Incisitermes minor (Hagen) (Isoptera: Kalotermitidae), were used to study the effect of termite density on signal strength. Interestingly, termite density did not significantly predict signal strength. The maximum reliable wood depth for detecting termites was 5 cm. Microwaves produced by Termatrac also showed good penetration into drywall and produced detectable signals even on a single drywood termite which confirms manufacturer's claim. Suggestions on using and improving microwaves technology for detecting termites is provided which can potentially be applied to other types of insects and noninsect animals.

摘要

在建筑物中检测干木白蚁极具挑战性。微波技术(Termatrac T3i)是一种用于检测建筑物中干木白蚁的无损方法。Termatrac设备及其移动应用程序在检测昆虫活动时会提供一个条形图和一个折线图,但解读这些图表非常主观。在本文中,使用一种新方法对Termatrac的输出信号进行量化,以研究在实验室模拟干墙系统中,墙体层、木材类型和白蚁密度对以曲线下面积衡量的信号强度的影响。在Termatrac T3i的最大灵敏度(增益:10)下进行了两项实验。在实验I中,使用HEXBUG Nano作为运动/振动源,并使用了两种木材类型,其中墙体层显著预测了信号强度,但木材类型没有。在实验II中,使用了两种不同密度的活的西部干木白蚁,即小截头蚁(Hagen)(等翅目:木白蚁科),来研究白蚁密度对信号强度的影响。有趣的是,白蚁密度并未显著预测信号强度。检测白蚁的最大可靠木材深度为5厘米。Termatrac产生的微波也显示出对干墙有良好的穿透性,即使对于单个干木白蚁也能产生可检测到的信号,这证实了制造商的说法。本文还提供了关于使用和改进微波技术检测白蚁的建议,这些建议可能适用于其他类型的昆虫和非昆虫动物。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验