Suppr超能文献

采用增材或减材制造技术生产的金属物体的几何精度:一项体外比较研究。

Geometrical accuracy of metallic objects produced with additive or subtractive manufacturing: A comparative in vitro study.

机构信息

Department of Prosthodontics, Faculty of Odontology, Malmö University, Smedjegatan 16, 214 21 Malmö, Sweden.

出版信息

Dent Mater. 2018 Jul;34(7):978-993. doi: 10.1016/j.dental.2018.03.009. Epub 2018 Apr 7.

Abstract

OBJECTIVE

To evaluate the accuracy and precision of objects produced by additive manufacturing systems (AM) for use in dentistry and to compare with subtractive manufacturing systems (SM).

METHODS

Ten specimens of two geometrical objects were produced by five different AM machines and one SM machine. Object A mimics an inlay-shaped object, while object B imitates a four-unit bridge model. All the objects were sorted into different measurement dimensions (x, y, z), linear distances, angles and corner radius.

RESULTS

None of the additive manufacturing or subtractive manufacturing groups presented a perfect match to the CAD file with regard to all parameters included in the present study. Considering linear measurements, the precision for subtractive manufacturing group was consistent in all axes for object A, presenting results of <0.050mm. The additive manufacturing groups had consistent precision in the x-axis and y-axis but not in the z-axis. With regard to corner radius measurements, the SM group had the best overall accuracy and precision for both objects A and B when compared to the AM groups.

SIGNIFICANCE

Within the limitations of this in vitro study, the conclusion can be made that subtractive manufacturing presented overall precision on all measurements below 0.050mm. The AM machines also presented fairly good precision, <0.150mm, on all axes except for the z-axis. Knowledge regarding accuracy and precision for different production techniques utilized in dentistry is of great clinical importance. The dental community has moved from casting to milling and additive techniques are now being implemented. Thus all these production techniques need to be tested, compared and validated.

摘要

目的

评估用于牙科的增材制造系统(AM)制造的物体的准确性和精密度,并与减材制造系统(SM)进行比较。

方法

使用五台不同的 AM 机器和一台 SM 机器生产了两种几何物体的十个样本。物体 A 模仿嵌体形状的物体,而物体 B 模仿四单位桥模型。所有物体都分为不同的测量尺寸(x、y、z)、线性距离、角度和角半径。

结果

在所研究的所有参数中,没有一个增材制造或减材制造组与 CAD 文件完全匹配。考虑线性测量,对于物体 A,减材制造组在所有轴上的精度均一致,结果<0.050mm。增材制造组在 x 轴和 y 轴上具有一致的精度,但在 z 轴上则不一致。关于角半径测量,与 AM 组相比,SM 组在物体 A 和 B 上均具有最佳的整体准确性和精密度。

意义

在本体外研究的限制内,可以得出结论,减材制造在所有测量值<0.050mm 时均具有整体精度。AM 机在所有轴上(除 z 轴外)的精度也相当好,<0.150mm。了解牙科中使用的不同生产技术的准确性和精密度具有重要的临床意义。牙科界已经从铸造转向铣削,并且现在正在实施增材技术。因此,所有这些生产技术都需要进行测试、比较和验证。