Suppr超能文献

上肢假肢性能能力评估量表(CAPPFUL)的编制及心理测量学验证。

Development and Psychometric Validation of Capacity Assessment of Prosthetic Performance for the Upper Limb (CAPPFUL).

机构信息

Department of Psychology, University of North Texas, Denton, TX.

Clinical Services, Advanced Arm Dynamics, Redondo Beach, CA.

出版信息

Arch Phys Med Rehabil. 2018 Sep;99(9):1789-1797. doi: 10.1016/j.apmr.2018.04.021. Epub 2018 May 16.

Abstract

OBJECTIVES

(1) To develop a performance-based measure for adult upper limb (UL) prosthetic functioning through broad (ie, overall performance) and functional domain-specific (eg, control skills) assessment of commonplace activities; (2) to conduct initial psychometric evaluation of the Capacity Assessment of Prosthetic Performance for the Upper Limb (CAPPFUL).

DESIGN

Internal consistency of CAPPFUL and interrater reliability for task, functional domain, and full-scale (sub)scores among 3 independent raters were estimated. Known-group validity was examined comparing scores by amputation level. Convergent validity was assessed between CAPPFUL and 2 hand dexterity or function tests; discriminant validity was assessed against self-reported disability.

SETTING

Six prosthetic rehabilitation centers across the United States.

PARTICIPANTS

Subjects (N=60) with UL amputation using a prosthesis.

INTERVENTIONS

Not applicable.

MAIN OUTCOME MEASURES

Not applicable.

RESULTS

Interrater reliability was excellent for scoring on the task, domain, and full-scale scores (intraclass correlation coefficients=.88-.99). Internal consistency was good (α=.79-.82). Generally, subjects with higher UL amputation levels scored lower (worse) than subjects with lower UL amputation levels. CAPPFUL demonstrated strong correlations with measures of hand dexterity or functioning (r=-.58 to .72) and moderate correlation with self-reported disability (r=-.35).

CONCLUSIONS

CAPPFUL was designed as a versatile, low-burden measure of prosthesis performance for any UL functional prosthetic device type and any UL amputation level. CAPPFUL assesses overall performance and 5 functional performance domains during completion of 11 tasks that require movement in all planes while manipulating everyday objects requiring multiple grasp patterns. Psychometric evaluation indicates good interrater reliability, internal consistency, known-group validity, and convergent and discriminant validity.

摘要

目的

(1)通过对常见活动进行广泛(即整体表现)和功能特定领域(如控制技能)评估,为成人上肢(UL)假肢功能开发基于表现的测量方法;(2)对手臂假肢表现能力评估(CAPPFUL)进行初步心理计量学评估。

设计

在 3 位独立评估者中,评估 CAPPFUL 的内部一致性和任务、功能领域和全尺度(子)评分的组内信度。通过比较截肢水平的评分来检查已知组的有效性。通过与 2 项手部灵巧度或功能测试评估 CAPPFUL 的收敛效度;通过与自我报告的残疾评估来评估区分效度。

地点

美国 6 个假肢康复中心。

参与者

使用假肢的 UL 截肢患者(N=60)。

干预措施

不适用。

主要观察指标

不适用。

结果

在任务、领域和全尺度评分方面,评分的组内信度极好(组内相关系数=.88-.99)。内部一致性良好(α=.79-.82)。一般来说,上肢截肢水平较高的患者的得分较低(较差),而上肢截肢水平较低的患者的得分较高(较好)。CAPPFUL 与手部灵巧度或功能的测量值(r=-.58 至.72)具有很强的相关性,与自我报告的残疾(r=-.35)具有中度相关性。

结论

CAPPFUL 旨在作为一种通用、低负担的测量方法,用于评估任何 UL 功能性假肢设备类型和任何 UL 截肢水平的假肢性能。CAPPFUL 通过完成 11 项需要在所有平面上移动并操纵需要多种抓握模式的日常物体的任务,评估整体性能和 5 个功能性能领域。心理计量学评估表明具有良好的组内信度、内部一致性、已知组有效性以及收敛和区分效度。