咽食管段内单向和圆周测压测量的比较:一项探索性研究。

Comparison of unidirectional and circumferential manometric measures within the pharyngoesophageal segment: an exploratory study.

作者信息

Guiu Hernandez Esther, Gozdzikowska Kristin, Jones Richard, Huckabee Maggie-Lee

机构信息

Department of Communication Disorders, University of Canterbury, Christchurch, New Zealand.

The Rose Centre for Stroke Recovery and Research, The University of Canterbury, Christchurch, New Zealand.

出版信息

Eur Arch Otorhinolaryngol. 2018 Sep;275(9):2303-2310. doi: 10.1007/s00405-018-5019-z. Epub 2018 Jun 26.

Abstract

BACKGROUND

Notable differences have been identified between low-resolution manometry (LRM) and high-resolution manometry (HRM) in normative data.

OBJECTIVE

This study aimed to investigate within-subject differences between unidirectional LRM and circumferential HRM solid-state measurement sensors in the pharyngoesophageal segment during swallowing.

METHODS

Ten healthy subjects (mean 26.9 years) were evaluated with both a 2.10 mm unidirectional catheter and a 2.75 mm circumferential catheter, with randomized order of catheter placement. Unidirectional measurements were made in four directions (posterior, anterior, right-lateral, left-lateral). Pressures and durations were analyzed to compare (1) posterior to anterior and lateral recordings and (2) posterior and average-LRM measures (C-LRM) to HRM measures at same anatomical location.

RESULTS

No significant differences were found in any of the measures across the four radial directions. A lower amplitude was measured in C-LRM compared to HRM for pharyngeal sensors (LRM Sensor 1: - 39.7 mmHg; Sensor 2: - 61.4 mmHg). Compared with posterior-LRM, HRM recorded higher UES pressures (- 12.8 mmHg) and longer UES relaxation durations (- 0.31 s).

CONCLUSION

This exploratory study is the first to compare within-subject pressures between unidirectional LRM and circumferential HRM. Substantial differences in pharyngeal manometric measures were found, particularly with regard to UES function. This is clinically important as manometry is uniquely able to evaluate UES function and clarify differential diagnoses in patients with dysphagia.

摘要

背景

已确定低分辨率测压法(LRM)和高分辨率测压法(HRM)在标准数据方面存在显著差异。

目的

本研究旨在调查吞咽过程中咽食管段单向LRM和环形HRM固态测量传感器的受试者内差异。

方法

对10名健康受试者(平均26.9岁)使用2.10毫米单向导管和2.75毫米环形导管进行评估,导管放置顺序随机。在四个方向(后、前、右侧、左侧)进行单向测量。分析压力和持续时间以比较:(1)后向与前向及侧向记录;(2)相同解剖位置的后向和平均LRM测量值(C-LRM)与HRM测量值。

结果

在四个径向方向上的任何测量中均未发现显著差异。与HRM相比,C-LRM测量的咽部传感器振幅较低(LRM传感器1:-39.7mmHg;传感器2:-61.4mmHg)。与后向LRM相比,HRM记录的UES压力更高(-12.8mmHg),UES松弛持续时间更长(-0.31秒)。

结论

这项探索性研究首次比较了单向LRM和环形HRM的受试者内压力。发现咽部测压测量存在显著差异,尤其是在UES功能方面。这在临床上很重要,因为测压法能够独特地评估UES功能并明确吞咽困难患者的鉴别诊断。