Abstract

PURPOSE

The purpose of this study was to evaluate the accuracy of pupil fields and determine the normative pupillary response data by age using a newly developed head-mounted perimeter.

METHODS

A total of 100 healthy subjects (age, 20 to 68 y) were enrolled. The newly developed head-mounted perimeter "imo" was used to measure the percentage pupil constriction (PPC) as response to a stimulus at all 36 test points of the visual field. Goldmann size III and V stimuli at 0, 8, and 11 decibels (dB) under 31.4, 6, and 3 apostilbs (asb) background were presented. The PPC correlations (r) of the right and left eyes were examined. Reproducibility was determined with the coefficient of variation (CV) and a Bland-Altman plot. By a simple bootstrap method, the mean PPC were analyzed as normative data in all 36 test points.

RESULTS

Excellent correlation between both eyes was obtained for Goldmann size V stimuli, target luminance of 0 dB, and a background luminance of 31.4 asb (r=0.83; P<0.001). From the test-retest CV peripheral areas have low reproducibility compared with central areas. With a Goldmann size V target, there was a steeper decline of the PPC from the center field to the periphery field, and the temporal field PPC was larger than the nasal field. No major differences were observed between the PPC data and the age groups by decade (eg, center 3 degrees; P=0.223-0.913).

CONCLUSIONS

Normative PPC data might well be useful for assessing objective visual fields with the newly developed head-mounted perimeter.

摘要

目的

本研究旨在评估新型头戴式周边视野计的瞳孔面积测量准确性,并确定按年龄划分的正常瞳孔反应数据。

方法

共纳入 100 名健康受试者(年龄 20 至 68 岁)。采用新型头戴式周边视野计“imo”,在 31.4、6 和 3 个 apostilb(asb)背景亮度下,对 0、8 和 11 分贝(dB)的 Goldmann 大小 III 和 V 刺激物在所有 36 个视野测试点进行刺激,测量瞳孔收缩百分比(PPC)。检查右眼和左眼的 PPC 相关性(r)。通过变异系数(CV)和 Bland-Altman 图确定重复性。采用简单的自举法,以所有 36 个测试点的正常数据分析平均 PPC。

结果

在 Goldmann 大小 V 刺激物、目标亮度为 0dB 和背景亮度为 31.4asb 时,双眼相关性极佳(r=0.83;P<0.001)。与中央区域相比,周边区域的测试-再测试 CV 具有较低的可重复性。对于 Goldmann 大小 V 目标,从中心视野到周边视野,PPC 下降幅度较大,颞侧视野的 PPC 大于鼻侧视野。PPC 数据与按十年划分的年龄组之间无明显差异(例如,中心 3 度;P=0.223-0.913)。

结论

新型头戴式周边视野计的正常 PPC 数据可能对评估客观视野具有重要意义。