Liu Bei, Chen Ping, Song Chaojun, Li Na, Tian Ying, Dong Yun, Zhang Yun, Li Qi
Department of Medical Technology, Xi'an Medical University, Xi'an 710021; Department of Immunology, Air Force Military Medical University, Xi'an 710032, China. *Corresponding author, E-mail:
Department of Neurology, First Affiliated Hospital, Air Force Military Medical University, Xi'an 710032, China.
Xi Bao Yu Fen Zi Mian Yi Xue Za Zhi. 2018 Apr;34(4):315-319.
Objective To establish a chemiluminescent immunoassay(CLIA) for the detection of soluble CD100 (sCD100) and evaluate its preliminary clinical application for the detection of sCD100 in clinical cerebrospinal fluid samples. Methods Ascites were prepared using two hybridomas secreting monoclonal antibody (mAb) to CD100, and the antibodies were purified. Based on sandwich ELISA, the experiment conditions were optimized and the CLIA for detecting sCD100 was established. The sensitivity and stability of CLIA were evaluated. The level of sCD100 in cerebrospinal fluid samples of patients (n=18) was detected. Results CLIA exhibited high performance within a dynamic range 0.098-12.5 ng/mL, and the limit of detection (LOD) was 0.12 ng/mL. The intra-assay coefficient variations (CV) were between 3.8%-6.6% and inter-assay CV were 6.2%-14.1%. Using CLIA, we examined the level of sCD100 in cerebrospinal fluid of viral encephalitis patients. The results showed the level of sCD100 in the patients were higher than that in normal controls. Two cases of them were 9.4 and 13.8 times higher than the normal mean value of control group. Conclusion A rapid, sensitive and stable CLIA for detecting sCD100 has been successfully established, which can be used for the quantitative detection of trace sCD100 in cerebrospinal fluid samples.
目的 建立一种检测可溶性CD100(sCD100)的化学发光免疫分析法(CLIA),并评估其在临床脑脊液样本中检测sCD100的初步临床应用价值。方法 利用两株分泌抗CD100单克隆抗体(mAb)的杂交瘤细胞制备腹水,并对抗体进行纯化。基于夹心酶联免疫吸附测定法(ELISA),优化实验条件,建立检测sCD100的CLIA。评估CLIA的灵敏度和稳定性。检测18例患者脑脊液样本中sCD100的水平。结果 CLIA在0.098 - 12.5 ng/mL的动态范围内表现出良好性能,检测限(LOD)为0.12 ng/mL。批内变异系数(CV)在3.8% - 6.6%之间,批间CV为6.2% - 14.1%。使用CLIA检测病毒性脑炎患者脑脊液中sCD100的水平。结果显示患者sCD100水平高于正常对照组。其中两例分别比对照组正常均值高9.4倍和13.8倍。结论 成功建立了一种快速、灵敏且稳定的检测sCD100的CLIA,可用于脑脊液样本中痕量sCD100的定量检测。