评估18F-FDG PET/CT检测1型神经纤维瘤病中神经纤维瘤恶变最常用的(半)定量参数。

Evaluation of the most commonly used (semi-)quantitative parameters of 18F-FDG PET/CT to detect malignant transformation of neurofibromas in neurofibromatosis type 1.

作者信息

Brinkman Marloes, Jentjens Sander, Boone Kitty, Anten Monique, Stumpel Constance T R M, Nelemans Patty J, van Kroonenburgh Marinus J P G

机构信息

Department of Neurology.

Department of Radiology and Nuclear Medicine.

出版信息

Nucl Med Commun. 2018 Nov;39(11):961-968. doi: 10.1097/MNM.0000000000000889.

Abstract

In patients with neurofibromatosis type 1, transformation of neurofibromas into a malignant peripheral nerve sheath tumor (MPNST) is a severe complication of the disease. Fluorine-18-fluorodeoxyglucose PET/computed tomography (PET/CT) is a viable option for detecting malignant tumors in neurofibromatosis type 1 patients. The aim of this review was to assess the diagnostic performance of the most frequently used parameters of PET/CT in detecting MPNST. An extensive computer search was performed using the Cochrane Library, Pubmed, and Medline/Embase databases. Two reviewers independently extracted data of relevant studies and assessed the methodological quality (QUADAS-2). The diagnostic performance of PET/CT parameters in individual studies was determined by calculating a diagnostic odds ratio (DOR) using the absolute numbers of true-positive, true-negative, false-positive, and false-negative test results. A total of eight studies were included, of which three evaluated the standardized uptake value as a diagnostic parameter, two assessed the tumor-to-liver (T/L) ratio, and three articles described both parameters. The cut-off values for maximum standardized uptake value (SUVmax) ranged from 3.2 to 4.5; for the T/L ratio, the cut-off values were between 1.0 and 4.3. The sensitivity and specificity ranged from 90 to 100% and from 80 to 100%, respectively (SUVmax). T/L ratios were associated with 92-100% sensitivity and 72-94% specificity. The corresponding DORs ranged from 57 to 145 (SUVmax) and 35 to 655 (T/L ratio). Both the SUV and the T/L ratio are associated with high sensitivity combined with acceptable specificity in detecting MPNST. There is a tendency toward higher DORs using the T/L ratio, but the number of studies is limited.

摘要

在1型神经纤维瘤病患者中,神经纤维瘤转变为恶性外周神经鞘瘤(MPNST)是该疾病的一种严重并发症。氟-18-氟脱氧葡萄糖PET/计算机断层扫描(PET/CT)是检测1型神经纤维瘤病患者恶性肿瘤的一种可行选择。本综述的目的是评估PET/CT最常用参数在检测MPNST中的诊断性能。使用Cochrane图书馆、PubMed和Medline/Embase数据库进行了广泛的计算机检索。两名评价者独立提取相关研究的数据并评估方法学质量(QUADAS-2)。通过使用真阳性、真阴性、假阳性和假阴性检测结果的绝对数计算诊断比值比(DOR)来确定个体研究中PET/CT参数的诊断性能。共纳入八项研究,其中三项评估标准化摄取值作为诊断参数,两项评估肿瘤与肝脏(T/L)比值,三篇文章同时描述了这两个参数。最大标准化摄取值(SUVmax)的截断值范围为3.2至4.5;对于T/L比值,截断值在1.0至4.3之间。敏感性和特异性分别为90%至100%和80%至100%(SUVmax)。T/L比值的敏感性为92%至100%,特异性为72%至94%。相应的DOR范围为57至145(SUVmax)和35至655(T/L比值)。SUV和T/L比值在检测MPNST时均具有高敏感性和可接受的特异性。使用T/L比值时DOR有升高趋势,但研究数量有限。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验