Bacterial contamination and subsequent infections are a major threat to human health. An early detection in the food chain, clinics or the environment, is key to limit this threat. We present a new concept to develop low-cost hand-held devices for the ultra-sensitive and specific detection of bacteria in a one-step process of 2-8h, directly from complex raw samples. This approach is based on a novel microfluidic magnetic fluidized bed. It reaches a 4CFU (colony forming unit) sensitivity with high quantification accuracy in a large dynamic range of 100-10CFU/mL. The versatility of the approach was demonstrated with the detection of different bacteria strains, among which Salmonella Typhimurium and E. coli O157:H15. Additionally, the method is sensitive to infectious bacteria only, a criterion requested by main applications and currently requiring additional culture steps of one to several days.
细菌污染及随后的感染对人类健康构成重大威胁。在食物链、诊所或环境中进行早期检测是限制这种威胁的关键。我们提出了一个新概念,即开发低成本手持设备,用于在2至8小时的一步过程中直接从复杂的原始样本中超灵敏且特异性地检测细菌。这种方法基于一种新型微流控磁流化床。它在100 - 10CFU/mL的大动态范围内,以高定量精度达到4CFU(菌落形成单位)的灵敏度。该方法的通用性通过检测不同细菌菌株得到了证明,其中包括鼠伤寒沙门氏菌和大肠杆菌O157:H15。此外,该方法仅对感染性细菌敏感,这是主要应用所要求的标准,而目前这需要一到几天的额外培养步骤。