Suppr超能文献

双焦点衍射型单片式人工晶状体在老视患者中的双侧植入:一项前瞻性病例系列研究。

Bilateral Implantation of a Single-Piece Bifocal Diffractive Intraocular Lens in Presbyopic Patients: A Prospective Case Series.

机构信息

Department of Ophthalmology, Hong Kong Sanatorium and Hospital, Hong Kong.

出版信息

Asia Pac J Ophthalmol (Phila). 2019 Jan-Feb;8(1):12-21. doi: 10.22608/APO.2018152. Epub 2018 Sep 27.

Abstract

PURPOSE

To report visual outcomes and quality after bilateral implantation of a single-piece diffractive multifocal intraocular lens (MIOL) with a bifocal design.

DESIGN

Prospective, observational case series.

METHODS

All presbyopic subjects were implanted with the ZMB00 MIOL (Abbott Medical Optics) at the Hong Kong Sanatorium and Hospital. We evaluated the distance, intermediate, and near visual acuity (VA) under photopic and mesopic conditions; contrast sensitivity with and without glare under photopic and mesopic conditions; quality of vision; and rate of spectacle independence.

RESULTS

A total of 36 subjects were included. No intraoperative complications developed. At the 6-month visit, the mean (± standard deviation) monocular uncorrected VAs at distance, intermediate, and near were 0.01 ± 0.12, 0.26 ± 0.17, and 0.09 ± 0.08, respectively. The respective mean binocular uncorrected VAs were -0.05 ± 0.09, 0.12 ± 0.13, and 0.04 ± 0.06. No eyes lost any corrected distance VA. The binocular contrast sensitivity was significantly better without glare than with glare under photopic and mesopic conditions ( < 0.05 for all spatial frequencies under both conditions). A total of 21 (58%) and 21 subjects (58%) reported halo and glare, respectively. Thirty subjects (83%) reported complete spectacle independence.

CONCLUSIONS

Bilateral implantation of the bifocal MIOL in presbyopic patients with or without cataract was safe and resulted in satisfactory vision and a high rate of spectacle independence. Halos and glare were common.

摘要

目的

报告具有双焦点设计的单片衍射多焦点人工晶状体(MIOL)双侧植入后的视觉效果和质量。

设计

前瞻性、观察性病例系列。

方法

所有远视患者均在香港疗养院和医院植入 ZMB00 MIOL(雅培医疗光学)。我们评估了明、暗光条件下的远距离、中距离和近距离视力(VA);明、暗光条件下有无眩光时的对比敏感度;视觉质量;以及不戴眼镜的独立性。

结果

共纳入 36 例患者。术中无并发症发生。在 6 个月的随访中,单眼未矫正的远距离、中距离和近距离 VA 的平均值(±标准差)分别为 0.01 ± 0.12、0.26 ± 0.17 和 0.09 ± 0.08。双眼未矫正的 VA 平均值分别为-0.05 ± 0.09、0.12 ± 0.13 和 0.04 ± 0.06。没有眼睛丧失任何矫正的远距离 VA。在明、暗光条件下,无眩光时双眼对比度敏感度明显优于有眩光时(所有空间频率下均<0.05)。21 例(58%)和 21 例(58%)患者分别报告有晕影和眩光。30 例(83%)患者报告完全不戴眼镜。

结论

在有或无白内障的远视患者中双侧植入双焦点 MIOL 是安全的,可获得满意的视力和较高的不戴眼镜的独立性。晕影和眩光很常见。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验