Suppr超能文献

颧上颌复合体骨折中的眼球内陷与眶容积变化:它们之间存在关联吗?

Enophthalmos and Orbital Volume Changes in Zygomaticomaxillary Complex Fractures: Is There a Correlation Between Them?

作者信息

Ebrahimi Ali, Kalantar Motamedi Mohammad Hosein, Rasouli Hamid Reza, Naghdi Navid

机构信息

Associate Professor of Plastic Surgery, Trauma Research Center, Baqiyatallah University of Medical Sciences, Tehran, Iran.

Professor of Oral and Maxillofacial Surgery, Trauma Research Center, Baqiyatallah University of Medical Sciences, Tehran, Iran.

出版信息

J Oral Maxillofac Surg. 2019 Jan;77(1):134.e1-134.e9. doi: 10.1016/j.joms.2018.08.028. Epub 2018 Sep 3.

Abstract

PURPOSE

The orbital cavity can be affected in zygomaticomaxillary complex (ZMC) fractures. The aim of this study was to assess the relation between orbital volume changes and enophthalmos in patients with ZMC fractures.

MATERIALS AND METHODS

A descriptive study of consecutive adult patients with recent isolated unilateral ZMC fractures who were otherwise healthy was performed from 2016 through 2017. Multislice computed tomographic (CT) scans were taken of all patients and enophthalmos was measured clinically using a Hertel exophthalmometer. In the axial plane, enophthalmos was measured on CT scan using Mimics software. Three-dimensional reconstruction and volume measurement of the orbital cavity also were performed using Mimics software. The correlation between clinical and radiographic amounts of enophthalmos was measured by Pearson correlation coefficient analysis. The association among radiographic enophthalmos, clinical enophthalmos, and volume changes of the orbital cavity was assessed by linear regression. The P value was set at .01.

RESULTS

Ninety-six patients (77 men, 19 women; mean age, 28.48 ± 8.29 yr) were assessed. Mean volumes of control and fractured bony orbits measured on CT scan were 29.02 ± 1.71 and 32.05 ± 2.22 cm, respectively (P < .001). There was a strong positive correlation between clinically and radiographically measured amounts of enophthalmos (correlation coefficient = 0.97; P < .001). Based on the linear regression model, for each 1-cm orbital volume change, clinical and radiographic enophthalmos amounts changed by 0.68 and 0.71 mm, respectively (P < .0001).

CONCLUSION

ZMC fractures commonly increase orbital volume and the degree of change is strongly correlated with enophthalmos.

摘要

目的

颧上颌复合体(ZMC)骨折可累及眶腔。本研究旨在评估ZMC骨折患者眼眶容积变化与眼球内陷之间的关系。

材料与方法

对2016年至2017年期间连续收治的近期孤立性单侧ZMC骨折且其他方面健康的成年患者进行描述性研究。对所有患者进行多层计算机断层扫描(CT),并使用Hertel眼球突出计临床测量眼球内陷情况。在轴位平面上,使用Mimics软件在CT扫描上测量眼球内陷。还使用Mimics软件进行眶腔的三维重建和容积测量。通过Pearson相关系数分析测量临床和影像学眼球内陷量之间的相关性。通过线性回归评估影像学眼球内陷、临床眼球内陷和眶腔容积变化之间的关联。P值设定为0.01。

结果

共评估了96例患者(77例男性,19例女性;平均年龄28.48±8.29岁)。CT扫描测量的对照侧和骨折侧骨性眼眶的平均容积分别为29.02±1.71和32.05±2.22cm³(P<0.001)。临床测量和影像学测量的眼球内陷量之间存在强正相关(相关系数=0.97;P<0.001)。基于线性回归模型,眼眶容积每变化1cm,临床和影像学眼球内陷量分别变化0.68和0.71mm(P<0.0001)。

结论

ZMC骨折通常会增加眼眶容积,且变化程度与眼球内陷密切相关。