Sertorio Fiammetta, Wong Michela Cing Yu, Incarbone Veronica, Pistorio Angela, Mattioli Girolamo, Magnano Gian Michele, Damasio Maria Beatrice
Radiology Department, IRCCS Istituto Giannina Gaslini, University of Genoa, Largo Gaslini 5, 16147, Genoa, Italy.
University of Genoa, Via Balbi, 5, 16126, Genoa, Italy.
Pediatr Radiol. 2019 Jan;49(1):105-113. doi: 10.1007/s00247-018-4252-3. Epub 2018 Oct 3.
Knowing that ureteropelvic junction obstruction is due to a crossing renal vessel is essential in choosing the appropriate surgical treatment.
To evaluate the diagnostic accuracy of non-contrast magnetic resonance (MR) angiography in identifying crossing renal vessels in children younger than 4 years old with unilateral hydronephrosis.
A retrospective review of preoperative MR urography of children with unilateral hydronephrosis was conducted by two independent readers. The presence or absence of crossing renal vessels was identified and compared with surgical findings.
Twenty-nine patients were included. The disagreement between MR angiography with and without contrast enhancement in detecting a crossing renal vessel was 8%. The disagreement between non-contrast-enhanced MR and surgical findings was 17%. The disagreement between contrast-enhanced MR angiography and surgical findings was 25%. The balanced triggered angiography without contrast enhancement had a sensitivity of 70% (95% confidence interval [CI]: 35-93%) and a specificity of 93% (95% CI: 66-100%). Contrast-enhanced MR angiography had a sensitivity of 56% (95% CI: 21-86%) and a specificity of 91%. (95% CI: 59-100%).
MR without contrast enhancement may be a reliable, valid and safe alternative to contrast-enhanced MR angiography for identifying crossing renal vessels.
了解肾盂输尿管连接处梗阻是由肾血管交叉所致对于选择合适的手术治疗至关重要。
评估非增强磁共振(MR)血管造影在识别4岁以下单侧肾积水儿童肾血管交叉情况时的诊断准确性。
两位独立阅片者对单侧肾积水儿童的术前MR尿路造影进行回顾性分析。确定是否存在肾血管交叉情况,并与手术结果进行比较。
纳入29例患者。增强与未增强MR血管造影在检测肾血管交叉方面的分歧率为8%。未增强MR与手术结果之间的分歧率为17%。增强MR血管造影与手术结果之间的分歧率为25%。未增强的平衡触发血管造影敏感性为70%(95%置信区间[CI]:35 - 93%),特异性为93%(95%CI:66 - 100%)。增强MR血管造影敏感性为56%(95%CI:21 - 86%),特异性为91%(95%CI:59 - 100%)。
对于识别肾血管交叉情况,未增强MR可能是增强MR血管造影一种可靠、有效且安全的替代方法。