Eur J Radiol. 2018 Nov;108:7-12. doi: 10.1016/j.ejrad.2018.09.011. Epub 2018 Sep 12.
To assess the utility of virtual monochromatic imaging (VMI) using a dual-layer spectral detector CT for electronic cleansing in fecal-tagging CT colonography (CTC).
This study included 35 patients who underwent fecal-tagging CTC with a dual-layer detector spectral CT scanner. Conventional images at 120 kVp and VMI at 40, 50, and 60 keV were reconstructed. Quantitative image quality parameters, i.e., tagging density and image noise, were compared and the visual image quality was scored on a four-point scale. We recorded the number of the colon segments with appropriate tagging density (≥300 HU) for each patient and used these data to compare the reconstructions. In addition, electronic cleansing performance was semi-quantitatively assessed using a four-point scale.
The mean tagging density on VMI was significantly higher than that on conventional 120 kVp images. The number of colon segments with appropriate tagging density on VMI were significantly higher than that on conventional 120 kVp images. There was no significant difference among the reconstructed images with respect to image noise. Scores for subjective image quality and electronic cleansing performance on VMI were significantly higher than those on conventional 120 kVp images.
With dual-layer spectral detector CT, VMI can yield significantly better fecal-tagged CTC image quality and improve electronic cleansing performance.
评估双层光谱探测器 CT 虚拟单色成像(VMI)在粪便标记 CT 结肠成像(CTC)中电子清洁的应用价值。
本研究纳入 35 例行粪便标记 CTC 检查的患者,使用双层探测器光谱 CT 扫描仪进行检查。重建常规 120 kVp 图像和 40、50、60 keV 的 VMI 图像。比较定量图像质量参数,即标记密度和图像噪声,并对图像质量进行四点评分。记录每位患者具有适当标记密度(≥300 HU)的结肠节段数,并使用这些数据进行比较。此外,使用四点评分法对电子清洁性能进行半定量评估。
VMI 的平均标记密度显著高于常规 120 kVp 图像。VMI 上具有适当标记密度的结肠节段数明显多于常规 120 kVp 图像。图像噪声方面,不同重建图像之间无显著差异。VMI 上的主观图像质量和电子清洁性能评分均显著高于常规 120 kVp 图像。
使用双层光谱探测器 CT,VMI 可显著提高粪便标记 CTC 图像质量,改善电子清洁效果。