Suppr超能文献

Use of ultrasound enhancing agents in transesophageal echocardiography to improve interpretive confidence of left atrial appendage thrombus.

作者信息

Doukky Rami, Donenberg Merrick J, Parker Jeremy, Kaplan Jonathan, Travers Chad, Soble Jeffrey S, Sattar Payman, Krishnan Kousik, Madias Christopher, Tracy Melissa, Feinstein Steven B

机构信息

Division of Cardiology, Cook County Health, Chicago, Illinois.

Division of Cardiology, Rush University Medical Center, Chicago, Illinois.

出版信息

Echocardiography. 2019 Feb;36(2):362-369. doi: 10.1111/echo.14228. Epub 2018 Dec 19.

Abstract

BACKGROUND

The value of ultrasound enhancing agents (UEA) in patients undergoing transesophageal echocardiography (TEE) for the exclusion of left atrial appendage (LAA) thrombi prior to direct current cardioversion (DCCV) is evolving.

METHODS

We retrospectively identified 88 consecutive TEEs, where a commercial UEA was used during LAA interrogation. De-identified non-enhanced (pre-UEA) and enhanced cine loop images (post-UEA) from the same subjects were randomly reviewed by four expert readers in a blinded fashion.

RESULTS

In 33% of the cases, UEA use was associated with a statistically insignificant improvement in physician confidence (scale, 0-3) in determining the presence or absence of a LAA thrombus (P = 0.071). In instances where non-enhanced images yielded an uncertain interpretation or when the left atrium contained spontaneous echo contrast (SEC), UEA use was associated with an improvement in interpretive confidence in 49% (P < 0.001) and 41% of the cases (P = 0.001), respectively. Overall, the absolute rate of hypothetical decision to proceed with DCCV rose by 9% with the application of UEA (P = 0.004). In instances where non-enhanced images were interpreted with limited confidence or when SEC was present, there were absolute increases of 16% (P < 0.001) and 21% (P < 0.001) in hypothetical procession to DCCV, respectively. In cases of a combination of limited interpretive confidence and SEC, UEA use was associated with a 29% absolute increase in the rate of procession to DCCV (P < 0.001).

CONCLUSIONS

In patients undergoing TEE interrogation of the LAA, the use of UEA is associated with an increase in the level of interpretive confidence and higher rates of theoretical procession to DCCV.