Comandante Christian, Chang Po-Cheng, Huang Yu-Chang, Chou Chung-Chuan
Division of Cardiology, Department of Medicine Chang Gung Memorial Hospital Linkou Taiwan.
Department of Electrophysiology Philippine Heart Center Manila Philippines.
Clin Case Rep. 2019 Feb 27;7(4):719-722. doi: 10.1002/ccr3.2075. eCollection 2019 Apr.
The presence of a Gore-Tex patch can create difficulty in performing transeptal puncture for atrial septal defect patients underwent atrial fibrillation ablation. The maneuverability and stability of using manually operated catheters via retrograde aortic approach could be overcome by a large-curved catheter to form a loop facilitating approachability to all parts of left atrium.
对于接受房颤消融术的房间隔缺损患者,Gore-Tex补片的存在会给经房间隔穿刺带来困难。通过逆行主动脉途径使用手动操作导管的可操作性和稳定性可通过大弯导管形成一个环来克服,该环有助于到达左心房的各个部位。