Suppr超能文献

通过表观扩散系数测量无创评估弥漫性中线胶质瘤 H3 K27M 突变状态。

Noninvasive assessment of H3 K27M mutational status in diffuse midline gliomas by using apparent diffusion coefficient measurements.

机构信息

Department of Medical Imaging, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-Sen University Cancer Center, Guangzhou, 510060, PR China; Department of Medical Imaging Center, Nanfang Hospital, Southern Medical University, Guangzhou, PR China.

Department of Pathology, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-Sen University Cancer Center, Guangzhou, 510060, PR China.

出版信息

Eur J Radiol. 2019 May;114:152-159. doi: 10.1016/j.ejrad.2019.03.006. Epub 2019 Mar 14.

Abstract

PURPOSE

H3 K27M-mutant diffuse midline gliomas are associated with worse prognosis than H3 K27M wild-type gliomas. In the present study, we sought to evaluate the conventional magnetic resonance imaging (cMRI) of H3 K27M-mutant glioma and examine whether diffusion-weighted imaging (DWI) derived apparent diffusion coefficient (ADC) could noninvasively predict H3 K27M mutational status in brain diffuse midline gliomas.

MATERIALS AND METHODS

The institutional review board approved this study and waived the requirement for informed consent. Thirty-eight patients with brain diffuse midline gliomas were retrospectively reviewed. The parameters of preoperative cMRI were evaluated. The minimal ADC, peritumoral ADC, ratio of minimal ADC, and ratio of peritumoral ADC were measured, and significant differences between the two groups were identified by logistic regression analysis adjusted for age and tumor location. Receiver operating characteristic curves and logistic regression analysis adjusted for age and tumor location were used to assess the diagnostic performances of the minimal ADC, peritumoral ADC, ratio of minimal ADC, and ratio of peritumoral ADC.

RESULTS

H3 K27M-mutant gliomas in different locations have diverse imaging characteristics. Minimal ADC, peritumoral ADC, ratio of minimal ADC, and ratio of peritumoral ADC values were significantly lower in the H3 K27M-mutant gliomas than in the wild-type gliomas (P < 0.05). The combination of ratio of minimal ADC and ratio of peritumoral ADC provided the largest area under the curve (AUC) of 0.872 in defining H3 K27M-mutational status.

CONCLUSIONS

The combination of ratio of minimal ADC and ratio of peritumoral ADC can noninvasively detect the H3 K27M mutational status in brain diffuse midline gliomas.

摘要

目的

H3 K27M 突变型弥漫中线胶质瘤的预后比 H3 K27M 野生型胶质瘤差。本研究旨在评估 H3 K27M 突变型脑弥漫中线胶质瘤的常规磁共振成像(cMRI),并探讨扩散加权成像(DWI)衍生的表观扩散系数(ADC)是否可以无创性预测脑弥漫中线胶质瘤的 H3 K27M 突变状态。

材料和方法

本研究经机构审查委员会批准,豁免了知情同意书的要求。回顾性分析了 38 例脑弥漫中线胶质瘤患者的病例资料。评估了术前 cMRI 的参数。测量了最小 ADC、瘤周 ADC、最小 ADC 比值和瘤周 ADC 比值,并通过逻辑回归分析调整年龄和肿瘤位置,确定两组之间的差异。使用受试者工作特征曲线和逻辑回归分析调整年龄和肿瘤位置,评估最小 ADC、瘤周 ADC、最小 ADC 比值和瘤周 ADC 比值的诊断性能。

结果

不同部位的 H3 K27M 突变型胶质瘤具有不同的影像学特征。H3 K27M 突变型胶质瘤的最小 ADC、瘤周 ADC、最小 ADC 比值和瘤周 ADC 比值均明显低于野生型胶质瘤(P<0.05)。最小 ADC 比值和瘤周 ADC 比值的组合在定义 H3 K27M 突变状态方面提供了最大的曲线下面积(AUC)为 0.872。

结论

最小 ADC 比值和瘤周 ADC 比值的组合可以无创性检测脑弥漫中线胶质瘤的 H3 K27M 突变状态。