步态和踏步任务期间臀中肌和臀小肌各节段肌内肌电图的组内可靠性。

Between session reliability of intramuscular electromyography for segments of gluteus medius and minimus during gait and stepping tasks.

作者信息

Green R A, Pizzari T, McClelland J, Zacharias A, Huynh P, Weerakkody N, Semciw A I

机构信息

Department of Pharmacy & Biomedical Sciences, La Trobe University, Bendigo, Australia; Sport, Exercise & Rehabilitation Research Focus Area, La Trobe University, Australia.

Sport, Exercise & Rehabilitation Research Focus Area, La Trobe University, Australia; School of Allied Health, La Trobe University, Melbourne, Australia.

出版信息

J Electromyogr Kinesiol. 2019 Aug;47:96-104. doi: 10.1016/j.jelekin.2019.05.015. Epub 2019 May 28.

Abstract

Between-session reliability of electromyographic data is important for confidence in interpreting the role of muscles in functional tasks but critical if these data are to be compared before and after an intervention that seeks to change pathological patterns of muscle activity. The gluteus medius (GMed) and minimus (GMin) are known to have functionally discrete segments that are highly active during stance phase of gait and stepping tasks. This study measured the between-session reliability of activity patterns, mean amplitudes and time to peak (TTP) activity of these muscle segments. Intramuscular electrodes were placed in 3 segments of GMed and 2 segments of GMin in 10 healthy young adults for each of two testing sessions held two weeks apart. Participants completed six repetitions of comfortable speed walking trials, step-up and step-down tasks with activity patterns for each muscle segment time- and amplitude-normalized and averaged across trials. Re-test reliability for was high for activity patterns (coefficient of mean correlation ranging from 0.890 to 0.998) across all tasks and muscle segments and only two pairwise comparisons showing differences in amplitude between sessions. With standardized data collection and analysis procedures, GMed and GMin muscle segment activity patterns show good between-session reliability for weightbearing tasks.

摘要

肌电图数据在不同测试时段之间的可靠性,对于确信解读肌肉在功能任务中的作用十分重要;而如果要在旨在改变肌肉活动病理模式的干预前后对这些数据进行比较,其可靠性则至关重要。已知臀中肌(GMed)和臀小肌(GMin)具有功能上离散的节段,在步态和跨步任务的站立阶段高度活跃。本研究测量了这些肌肉节段活动模式、平均振幅和峰值活动时间(TTP)在不同测试时段之间的可靠性。在10名健康年轻成年人中,将肌内电极置于GMed的3个节段和GMin的2个节段,进行相隔两周的两次测试。参与者完成了六次舒适速度步行试验、上台阶和下台阶任务,每个肌肉节段的活动模式按时间和振幅进行归一化处理,并在各试验中求平均值。所有任务和肌肉节段的活动模式再测试可靠性都很高(平均相关系数范围为0.890至0.998),只有两组配对比较显示不同测试时段之间的振幅存在差异。通过标准化的数据收集和分析程序,GMed和GMin肌肉节段的活动模式在负重任务中显示出良好的不同测试时段之间的可靠性。