Suppr超能文献

基于光纤的简约系统配置偏振敏感光学相干断层扫描技术

Fiber-based polarization-sensitive optical coherence tomography of a minimalistic system configuration.

作者信息

Moon Sucbei, Miao Yusi, Chen Zhongping

出版信息

Opt Lett. 2019 Jun 15;44(12):3150-3153. doi: 10.1364/OL.44.003150.

Abstract

We present a very simple method of constructing a polarization-sensitive optical coherence tomography (PS-OCT) system. An ordinary fiber-based swept-source OCT system was reconfigured for PS-OCT by adding a long section of polarization-maintaining fiber in the sample arm. Two polarization modes of a large group-delay difference formed spatially distinguished polarization channels. The depth-encoded information on the polarization states was retrieved by an amplitude-based analysis. We found that our method provides an economic scheme of PS-OCT. It demonstrates that an ordinary OCT system can be easily reconfigured for PS-OCT imaging if it has sufficient margins in the imaging range.

摘要

我们提出了一种构建偏振敏感光学相干断层扫描(PS-OCT)系统的非常简单的方法。通过在样品臂中添加一段长的保偏光纤,将一个普通的基于光纤的扫频源OCT系统重新配置用于PS-OCT。具有大群时延差的两个偏振模式形成了空间上可区分的偏振通道。通过基于幅度的分析来检索关于偏振态的深度编码信息。我们发现我们的方法提供了一种经济的PS-OCT方案。这表明,如果一个普通的OCT系统在成像范围内有足够的余量,那么它可以很容易地重新配置用于PS-OCT成像。

相似文献

2
Depth-encoded all-fiber swept source polarization sensitive OCT.
Biomed Opt Express. 2014 Aug 1;5(9):2931-49. doi: 10.1364/BOE.5.002931. eCollection 2014 Sep 1.
3
Full-range depth-encoded swept source polarization sensitive optical coherence tomography.
Opt Express. 2024 Mar 11;32(6):9374-9383. doi: 10.1364/OE.510970.
6
Parallel detection of Jones-matrix elements in polarization-sensitive optical coherence tomography.
Biomed Opt Express. 2019 Apr 8;10(5):2318-2336. doi: 10.1364/BOE.10.002318. eCollection 2019 May 1.
9
Dark-field polarization-sensitive optical coherence tomography.
Opt Express. 2015 May 18;23(10):12874-86. doi: 10.1364/OE.23.012874.
10
Effects of sample arm motion in endoscopic polarization-sensitive optical coherence tomography.
Opt Express. 2005 Jul 25;13(15):5739-49. doi: 10.1364/opex.13.005739.

引用本文的文献

1
Investigating the impact of different time delays between OCT signal and k-clock signal on the structural and vascular imaging in SS-OCT.
Biomed Opt Express. 2025 Feb 26;16(3):1225-1239. doi: 10.1364/BOE.553982. eCollection 2025 Mar 1.
2
Synthesizing the degree of polarization uniformity from non-polarization-sensitive optical coherence tomography signals using a neural network.
Biomed Opt Express. 2023 Mar 17;14(4):1522-1543. doi: 10.1364/BOE.482199. eCollection 2023 Apr 1.
3

本文引用的文献

1
Phase-stability optimization of swept-source optical coherence tomography.
Biomed Opt Express. 2018 Oct 9;9(11):5280-5295. doi: 10.1364/BOE.9.005280. eCollection 2018 Nov 1.
3
Passive optical module for polarization-sensitive optical coherence tomography systems.
Opt Express. 2017 Jun 26;25(13):14533-14544. doi: 10.1364/OE.25.014533.
4
Polarization sensitive optical coherence tomography - a review [Invited].
Biomed Opt Express. 2017 Feb 24;8(3):1838-1873. doi: 10.1364/BOE.8.001838. eCollection 2017 Mar 1.
5
Polarization Effects in Optical Coherence Tomography of Various Biological Tissues.
IEEE J Sel Top Quantum Electron. 1999 Jul-Aug;5(4):1200-1204. doi: 10.1109/2944.796347.
10
Single camera based spectral domain polarization sensitive optical coherence tomography.
Opt Express. 2007 Feb 5;15(3):1054-63. doi: 10.1364/oe.15.001054.