传统与激光激活根管冲洗对根尖冲洗液挤出的比较。

Comparison of apical irrigant solution extrusion among conventional and laser-activated endodontic irrigation.

机构信息

Department of Endodontics and Restaurative Dentistry, School of Dentistry, University of Rijeka, Braće Branchetta 20, 51 000, Rijeka, Croatia.

Department of Fluid Mechanics and Computational Engineering, Technical Faculty, University of Rijeka, Vukovarska ul. 58, Rijeka, Croatia.

出版信息

Lasers Med Sci. 2020 Feb;35(1):205-211. doi: 10.1007/s10103-019-02846-w. Epub 2019 Jul 18.

Abstract

The aim of this study was to determine the amount of extruded endodontic irrigant among needle-syringe irrigation (NSI) and laser-activated irrigation (LAI) regimens. Twenty extracted maxillary central incisors were prepared utilizing GT professional rotary files (size 40, taper 0.06). Irrigation was performed with two 27 G irrigation needles (notched open ended (ON) and single side vented (SV)) each at two different irrigant volumetric flow rates (VFR)-0.05 ml/s (3 ml/min) and 0.10 ml/s (6 ml/min). LAI was performed with Er:YAG (erbium-doped yttrium aluminum garnet) using different fiber types (X-Pulse-14/400 cylindrical tip, Preciso- 14/300 flat cylindrical tip, PIPS- 14/400 quartz tapered tip). The Er:YAG laser with a wavelength of 2940 nm (Lightwalker AT, Fotona, Ljubljana, Slovenia) was used according to the following protocol: 10 mJ per pulse, 15 Hz, pulse duration 50 μs. Irrigation time was 60 s for all protocols. Precision syringe pump (PSP) maintained constant irrigant volumetric flow rate. Apically extruded irrigant was collected and net weighed for each protocol (N = 10). Data were analyzed by t tests and Kruskal-Wallis. All LAI regimens had statistically significant lower irrigant extrusion compared with NSI except for the SV 27 G needle used with 0.05 ml/s VFR when compared with the Preciso fiber tip (p = 0,230). The largest amount of extruded irrigant was with the ON 27 G needle at the 0.10 ml/s VFR, while the smallest was after LAI with PIPS fiber tip. The lower quantity of apically extruded irrigant during LAI (X-Pulse and PIPS) points out a safer endodontic irrigation method compared with conventional irrigations.

摘要

本研究旨在确定针管注射器冲洗(NSI)和激光激活冲洗(LAI)方案中挤出的根管冲洗液量。二十颗上颌中切牙被 GT 专业旋转锉(40 号,锥度 0.06)制备。冲洗时使用两种 27G 冲洗针(开有缺口的末端(ON)和单侧通气(SV)),每种针在两种不同的冲洗液容积流速(VFR)-0.05ml/s(3ml/min)和 0.10ml/s(6ml/min)下进行冲洗。LAI 采用 Er:YAG(掺铒钇铝石榴石)激光,使用不同的光纤类型(X-Pulse-14/400 圆柱形尖端、Preciso-14/300 平圆柱形尖端、PIPS-14/400 石英锥形尖端)。波长为 2940nm 的 Er:YAG 激光(Lightwalker AT,Fotona,卢布尔雅那,斯洛文尼亚)根据以下方案使用:每个脉冲 10mJ,15Hz,脉冲持续时间 50μs。所有方案的冲洗时间均为 60s。精密注射器泵(PSP)维持恒定的冲洗液容积流速。收集并净称每个方案的根尖挤出冲洗液(N=10)。数据通过 t 检验和 Kruskal-Wallis 检验进行分析。除了与 Preciso 光纤尖端相比,SV 27G 针在 0.05ml/s VFR 时与 NSI 相比,所有 LAI 方案的冲洗剂挤出量均有统计学显著降低(p<0.05)。在 0.10ml/s VFR 时,ON 27G 针的挤出冲洗剂量最大,而在 LAI 后使用 PIPS 光纤尖端时挤出冲洗剂量最小。LAI(X-Pulse 和 PIPS)过程中根尖挤出的冲洗剂量较少,表明与传统冲洗相比,这是一种更安全的根管冲洗方法。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验