Manyoni M J, Goldstein L N, Wells M
Division of Emergency Medicine, Faculty of Health Sciences, University of the Witwatersrand.
S Afr J Surg. 2019 Jun;57(2):40-46.
One of the most important parameters that must be obtained when resuscitating a critically ill or injured paediatric patient is their weight. The best known paediatric weight estimation system is arguably the Broselow Tape, but the tape has been shown to be very inaccurate. The aim of this study was to determine and compare the accuracy of the Broselow tape, a modified Broselow tape system, the PAWPER XL tape and the hanging leg weight technique for potential utilisation in the paediatric resuscitation setting.
A convenience sample of 200 children between the ages of 1 month and 16 years were enrolled. All the children's weights were estimated using the Broselow tape, a habitus-modified Broselow tape system, the PAWPER XL tape and the hanging leg weight technique. Overall accuracy was evaluated using the percentage of weight estimations falling within 10% of actual weight (PW10).
The PAWPER XL tape performed the best, whilst the hanging leg weight technique performed the poorest with PW10s of 74% and 19.5%, respectively. The Broselow tape with and without habitus-modification only showed modest accuracy, with PW10s of 61.7% and 59.1% respectively.
The PAWPER XL tape performed significantly better than other weight estimation systems and is most appropriate for use in South African paediatric emergencies. The habitus-modified Broselow system produced only modest improvement in overall weight estimation accuracy of the Broselow tape.
在对危重症或受伤的儿科患者进行复苏时,必须获取的最重要参数之一是他们的体重。最广为人知的儿科体重估计系统当属布罗泽洛磁带(Broselow Tape),但已证明该磁带非常不准确。本研究的目的是确定并比较布罗泽洛磁带、改良的布罗泽洛磁带系统、PAWPER XL磁带和垂腿称重技术在儿科复苏环境中潜在应用的准确性。
纳入了200名年龄在1个月至16岁之间的儿童作为便利样本。使用布罗泽洛磁带、体型改良的布罗泽洛磁带系统、PAWPER XL磁带和垂腿称重技术对所有儿童的体重进行估计。使用体重估计值落在实际体重的10%范围内的百分比(PW10)来评估总体准确性。
PAWPER XL磁带表现最佳,而垂腿称重技术表现最差,PW10分别为74%和19.5%。有无体型改良的布罗泽洛磁带仅显示出适度的准确性,PW10分别为61.7%和59.1%。
PAWPER XL磁带的表现明显优于其他体重估计系统,最适合用于南非儿科急诊。体型改良的布罗泽洛系统在布罗泽洛磁带的总体体重估计准确性方面仅产生了适度的提高。