Suppr超能文献

根据第一只手术眼的屈光不正调整第二只眼的人工晶状体度数。

Adjustment of IOL power for the second eye based on refractive error of the first-operated eye.

作者信息

Zhang Jie, Ning Xiao-Na, Yan Hong

机构信息

Department of Ophthalmology, Tangdu Hospital, the Fourth Military Medical University, Xi'an 710038, Shaanxi Province, China.

Xi'an No.4 Hospital, Shaanxi Eye Hospital, Affiliated Guangren Hospital School of Medicine, Xi'an Jiaotong University, Xi'an 710004, Shaanxi Province, China.

出版信息

Int J Ophthalmol. 2019 Aug 18;12(8):1348-1350. doi: 10.18240/ijo.2019.08.18. eCollection 2019.

Abstract

This study was to estimate refractive status of the second eye of those undergo bilateral cataract surgery based on the first-operated eye, and to evaluate the refractive error (RE) in the second eye after correcting 50% of the first-operated eye's error when it exceeded ±0.50 diopter (D). In this prospective study, 80 patients were scheduled for cataract surgery in the second eye, who underwent cataract surgery in first eye 1-3mo previously. The RE of each eye postoperatively was determined according to SRK/T formula. When the first-eye refractive error (FERE) exceeded ±0.5 D, the intraocular lens (IOL) power of the second eye was adjusted 50% of the FERE. The second-eye refractive error (SERE) was measured 1mo after surgery. The FERE exceeded -0.50 D in 12 eyes (-0.675±0.16 D), and the adjusted SERE was -0.322±0.73 D (<0.05). The FERE exceeded +0.50 D in 8 eyes (1.533±1.14 D), and the adjusted SERE was 0.168±1.36 D (<0.05). The unadjusted SERE in 60 cases remained -0.38 to 0.42 D when the FERE within ±0.05 D. This prospective study confirmed that the prediction of the second eye could be improved by correcting 50% of FERE when this error exceeded ±0.50 D.

摘要

本研究旨在基于首次手术眼估计接受双眼白内障手术患者的第二只眼的屈光状态,并评估当首次手术眼的屈光不正超过±0.50屈光度(D)时,矫正其50%的误差后第二只眼的屈光不正(RE)情况。在这项前瞻性研究中,80例患者计划接受第二只眼的白内障手术,他们在1 - 3个月前已接受了第一只眼的白内障手术。术后每只眼的RE根据SRK/T公式确定。当第一眼屈光不正(FERE)超过±0.5 D时,第二只眼的人工晶状体(IOL)度数调整为FERE的50%。术后1个月测量第二只眼的屈光不正(SERE)。12只眼的FERE超过 - 0.50 D(-0.675±0.16 D),调整后的SERE为 - 0.322±0.73 D(P<0.05)。8只眼的FERE超过 + 0.50 D(1.533±1.14 D),调整后的SERE为0.168±1.36 D(P<0.05)。当FERE在±0.05 D范围内时,60例患者未调整的SERE保持在 - 0.38至0.42 D之间。这项前瞻性研究证实,当FERE超过±0.50 D时,通过矫正其50%的误差可改善对第二只眼的预测。

相似文献

本文引用的文献

9
Sources of error in intraocular lens power calculation.人工晶状体屈光力计算中的误差来源。
J Cataract Refract Surg. 2008 Mar;34(3):368-76. doi: 10.1016/j.jcrs.2007.10.031.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验