Suppr超能文献

采用戈尔 VIABAHN VBX 球囊扩张式覆膜支架治疗局限性远端腹主动脉狭窄。

Treatment of focal distal abdominal aortic stenosis with the GORE VIABAHN VBX balloon expandable covered stent.

机构信息

Sanford Health Heart and Vascular Center, Bemidji, Minnesota.

出版信息

Catheter Cardiovasc Interv. 2020 Feb 15;95(3):457-461. doi: 10.1002/ccd.28478. Epub 2019 Sep 2.

Abstract

The incidence of focal infrarenal stenosis of the aorta is rare. Endovascular therapy has evolved as a first-line treatment of aortoiliac occlusive disease and has been shown to substantially improve health-related quality of life. The 8 French sheath compatible, GORE VIABAHN VBX (GORE Flagstaff, AZ) balloon expandable covered stent offers the traditional benefits of a balloon expandable covered stent with a design that improves on flexibility. We report three cases with the use of this system for treatment of infrarenal stenosis of the aorta.

摘要

腹主动脉局灶性狭窄的发病率较低。血管内治疗已发展成为主髂动脉闭塞性疾病的一线治疗方法,并已证明可显著改善与健康相关的生活质量。8F 鞘兼容的戈尔 VIABAHN VBX(戈尔旗杆市,AZ)球囊扩张覆膜支架提供了传统球囊扩张覆膜支架的优势,其设计提高了灵活性。我们报告了三例使用该系统治疗腹主动脉狭窄的病例。